Cooling Tower, 200, 380V - view 2
Cooling Tower, 200, 380V - view 3
Cooling Tower, 200, 380V - view 4
Cooling Tower, 200, 380V - view 5
Cooling Tower, 200, 380V - view 6

Cooling Tower, 200, 380V, 1650-7600mm, 630-3700mm, FRP

$243.00

Cooling Tower: 380V/50Hz/3Phase, power 0.18-22 kw(0.24-29.50hp). Supplied direct from the factory with the complete specification. Material: FRP. Certification: ISO9001.

Voltage
380V/50Hz/3Phase
Power(W)
0.18-22 kw(0.24-29.50hp)
Material
FRP
Warranty
1 Year
Place Of Origin
Jiangsu, China
Certification
ISO9001
  • Reply within one working day
  • Factory-direct pricing, OEM & ODM accepted
  • Full specification and test reports supplied
Also listed under

Get Factory Pricing

Free quotation direct from the manufacturer — price, MOQ and lead time, usually within one working day. No account needed.

Enquiring about Cooling Tower, 200, 380V, 1650-7600mm, 630-3700mm, FRP

Key specification for this cooling tower: 380V/50Hz/3Phase, power 0.18-22 kw(0.24-29.50hp). Everything below is reproduced from the factory data sheet. For a binding price and lead time, send the volume you need and where it ships to.

Key Features of This Cooling Tower

  • Power(W): 0.18-22 kw(0.24-29.50hp)
  • Voltage: 380V/50Hz/3Phase
  • Material: FRP
  • Noise Level: 40 dB and above
  • Warranty: 1 Year
  • Certification: ISO9001

Technical Specifications

Voltage 380V/50Hz/3Phase
Cooling Type Counter Flow
Power(W) 0.18-22 kw(0.24-29.50hp)
Material FRP
Core Components Motor
Machinery Test Report Provided
Warranty 1 Year
Video Outgoing-Inspection Provided
Control Method Touch
Noise Level 40 dB and above
Key Selling Points cooling tower
Place Of Origin Jiangsu, China
Weight (Kg) 46
Brand Name TOBEL
Dimension(L*W*H) 1075*1075*1830
After-Sales Service Provided Online support
Name cooling tower
Water Flow 7.8-781.2 m3/h
Water Pump Motor 0.18-22 kw
Height 1060-4720mm
Diameter Of Water Tray 1650-7600mm
Diameter Of Fan 630-3700mm
Certification ISO9001
Net Weight 50-4900kg
Selling Units Single item
Single Volume 0 cm³
Single Gross Weight 0.0 kg

Product Details

TOBEL Concept
Cooling Tower, 200, 380V - detail 1Cooling Tower, 200, 380V - detail 2
One-stop solution provider for cooling systems.
The company's cooling tower series includes: TBYT series counter-flow round tower、TBHT series low-noise cross-flow square tower、TBH-G series all-steel structure cross-flow square tower、TBNT series low-noise counter-flow square tower、TBN-G series all-steel counter-flow square tower Tower、TBNG series industrial counterflow square tower、TBB series closed cooling tower.
Cooling Tower, 200, 380V - detail 3Cooling Tower, 200, 380V - detail 4
Cooling Tower, 200, 380V - detail 5Cooling Tower, 200, 380V - detail 6
Cooling Tower, 200, 380V - detail 7Cooling Tower, 200, 380V - detail 8
Cooling Tower, 200, 380V - detail 9Cooling Tower, 200, 380V - detail 10
Cooling Tower, 200, 380V - detail 11Cooling Tower, 200, 380V - detail 12
Cooling Tower, 200, 380V - detail 13Cooling Tower, 200, 380V - detail 14
Cooling Tower, 200, 380V - detail 15Cooling Tower, 200, 380V - detail 16
TOBEL company refers to the GB/T7190-2018 formulated by the China Cooling Tower Industry Association (CCTI), the (CTI) STD-201 formulated by the American Refrigeration Institute and other standards, combined with the IS09001 quality system requirements, and gradually developed through rigorous and professional practice and improvement. We have improved a series of standardized standard products, which have the characteristics of good cooling effect, low noise, energy saving, no floating water, small size, compact structure, beautiful appearance, etc. We have obtained 1 invention patent and 9 utility model patents, and won the title of "National High-tech" Technology Enterprise" and other honorary titles.
Performance parameter table & structural diagram

TBYT series counter-flow round tower.

Optional Parts:Noise reduction components (accoustic screen&fan cylinder)、Vibration isolator&Rubber mat、High-temperature components、Sump Heater、Stainless Steel Framework/Bolts&Nuts
Cooling Tower, 200, 380V - detail 17Cooling Tower, 200, 380V - detail 18
Note: 1. The design working conditions of this series of cooling towers are: dry bulb temperature 31.5°C, wet bulb temperature 28°C, inlet water temperature 37°C, outlet water temperature 32°C, and atmospheric pressure 99.4kpa. 2. During the installation process of cooling tower pipelines, customers need to add Y-type filters, valves, pressure gauges and other auxiliary fittings at the water inlet. 3. The noise test point is the second point in the national standard GB7190.1-2008 (the horizontal distance between the tower air inlet direction and the tower wall is 1 times the diameter of the tower and 1.5 meters above the ground).
Cooling Tower, 200, 380V - detail 19Cooling Tower, 200, 380V - detail 20

TBHT series low-noise cross-flow square tower.

Optional Parts:Noise reduction components (accoustic screen&fan cylinder)、Handrail&safety caged ladder、Vibration isolator&Rubber mat、High-temperature components、Built-in water inlet pipe、Sump Heater、Stainless Steel Framework/Bolts&Nuts
Cooling Tower, 200, 380V - detail 21Cooling Tower, 200, 380V - detail 22
Note: 1. The design working conditions of this series of cooling towers are: dry bulb temperature 31.5°C, wet bulb temperature 28°C, inlet water temperature 37°C, outlet water temperature 32°C, and atmospheric pressure 99.4kpa. 2. During the installation process of cooling tower pipelines, customers need to add Y-type filters, valves, pressure gauges and other auxiliary fittings at the water inlet.
Cooling Tower, 200, 380V - detail 23Cooling Tower, 200, 380V - detail 24

TBNT series low-noise counter-flow square tower.

Optional Parts:Noise reduction components (accoustic screen&fan cylinder)、Handrail&safety caged ladder、Vibration isolator&Rubber mat、High-temperature components、Built-in water inlet pipe、Sump Heater、Stainless Steel Framework/Bolts&Nuts
Cooling Tower, 200, 380V - detail 25Cooling Tower, 200, 380V - detail 26
Note: 1. The design working conditions of this series of cooling towers are: dry bulb temperature 31.5°C, wet bulb temperature 28°C, inlet water temperature 37°C, outlet water temperature 32°C, and atmospheric pressure 99.4kpa. 2. During the installation process of cooling tower pipelines, customers need to add Y-type filters, valves, pressure gauges and other auxiliary fittings at the water inlet.
Cooling Tower, 200, 380V - detail 27Cooling Tower, 200, 380V - detail 28

TBB series closed cooling tower.

Note: 1. The design working conditions of this series of cooling towers are: dry bulb temperature 31.5°C, wet bulb temperature 28°C, inlet water temperature 37°C, outlet water temperature 32°C, and atmospheric pressure 99.4kpa. 2. During the installation process of cooling tower pipelines, customers need to add Y-type filters, valves and pressure gauges at the water inlet. 3. The dimensions described in the parameter table are only the dimensions of the host box and do not include the dimensions of the water tank and circulation pump.
Cooling Tower, 200, 380V - detail 29Cooling Tower, 200, 380V - detail 30
Cooling Tower, 200, 380V - detail 31Cooling Tower, 200, 380V - detail 32
Other Series
All-steel square cross-flow cooling tower
Cooling Tower, 200, 380V - detail 33Cooling Tower, 200, 380V - detail 34
All-steel square counterflow cooling tower
Cooling Tower, 200, 380V - detail 35Cooling Tower, 200, 380V - detail 36
Cooling tower accessories
Cooling Tower, 200, 380V - detail 37Cooling Tower, 200, 380V - detail 38
Craftsmanship
Cooling Tower, 200, 380V - detail 39Cooling Tower, 200, 380V - detail 40
Project Cases
Cooling Tower, 200, 380V - detail 41Cooling Tower, 200, 380V - detail 42
University
Cooling Tower, 200, 380V - detail 43Cooling Tower, 200, 380V - detail 44
Alcoholic beverage industry
Cooling Tower, 200, 380V - detail 45Cooling Tower, 200, 380V - detail 46
Food processing
Cooling Tower, 200, 380V - detail 47Cooling Tower, 200, 380V - detail 48
Printing and dyeing waste water
Cooling Tower, 200, 380V - detail 49Cooling Tower, 200, 380V - detail 50
Technology and new energy
Cooling Tower, 200, 380V - detail 51Cooling Tower, 200, 380V - detail 52
New materials
Cooling Tower, 200, 380V - detail 53Cooling Tower, 200, 380V - detail 54
Cooling Tower, 200, 380V - detail 55Cooling Tower, 200, 380V - detail 56
Cooling Tower, 200, 380V - detail 57Cooling Tower, 200, 380V - detail 58
Cooling Tower, 200, 380V - detail 59Cooling Tower, 200, 380V - detail 60
Cooling Tower, 200, 380V - detail 61Cooling Tower, 200, 380V - detail 62
Cooling Tower, 200, 380V - detail 63Cooling Tower, 200, 380V - detail 64
Cooling Tower, 200, 380V - detail 65Cooling Tower, 200, 380V - detail 66
Cooling Tower, 200, 380V - detail 67Cooling Tower, 200, 380V - detail 68

Ordering and Pricing

  • Minimum order quantity: 1 set
  • Volume pricing:
    • 1–9 set: US $264 / set
    • 10+ set: US $243 / set
  • Ships from: China
  • Customization: OEM and ODM accepted on qualifying volumes.

Frequently Asked Questions

What is the minimum order quantity for this cooling tower?

The standard minimum order quantity is 1 set. Trial orders can usually be arranged for buyers evaluating the product before a full production run.

What warranty is provided?

The manufacturer provides a 1 Year warranty. Spare parts and technical support remain available after the warranty period.

Which certifications does this cooling tower carry?

It is supplied with ISO9001 documentation, which covers the requirements of most import markets. Additional test reports can be issued on request.

Can the cooling tower be supplied for my local voltage?

The standard configuration is 380V/50Hz/3Phase. Alternative voltage and frequency builds are available when specified at the time of order.

Do you accept OEM or custom branding?

Yes. Custom logo, colour, packaging and specification changes are accepted on qualifying order volumes. Send your artwork and technical requirements with your enquiry.

How long does production and delivery take?

In-stock configurations typically ship within 7–15 days. Customised or large-volume orders are usually produced in 25–35 days, confirmed on order.

About the Manufacturer

This product is produced by Nantong Tobel Intelligent Controlling Equipment Co., Ltd., based in China. The company 9 years as a verified Alibaba.com supplier, operates its own manufacturing. Browse the full Nantong Tobel Intelligent Controlling Equipment Co., Ltd. range on HVACR Nexus.

Voltage

380V/50Hz/3Phase

Cooling Type

Counter Flow

Power(W)

0.18-22 kw(0.24-29.50hp)

Material

FRP

Core Components

Motor

Machinery Test Report

Provided

Warranty

1 Year

Video Outgoing-Inspection

Provided

Control Method

Touch

Noise Level

40 dB and above

Key Selling Points

cooling tower

Place Of Origin

Jiangsu, China

Weight (Kg)

46

Brand Name

TOBEL

Dimension(L*W*H)

1075*1075*1830

After-Sales Service Provided

Online support

Name

cooling tower

Water Flow

7.8-781.2 m3/h

Water Pump Motor

0.18-22 kw

Height

1060-4720mm

Diameter Of Water Tray

1650-7600mm

Diameter Of Fan

630-3700mm

Certification

ISO9001

Net Weight

50-4900kg

Selling Units

Single item

Single Volume

0 cm³

Single Gross Weight

0.0 kg

More from Nantong Tobel Intelligent Controlling Equipment Co., Ltd.

Other equipment from the same manufacturer — one enquiry can cover several items.

Compare Other Cooling Towers

Alternatives in the same category, from different verified suppliers.

Explore related