Cooling tower — 380 V, air flow rate 60000~160000 m³/h. The complete factory specification follows. Made by Wuxi Master Cooling Machinery Manufacturing Co., Ltd. (5 years on the platform, typical reply ≤6h). Send your target quantity and destination for a firm quotation with current lead times.
Key Features of This Cooling Tower
- Model Number: DLZF-18, DLZF-22(7.5kw), DLZF-22(11kw 580rpm), DLZF-22(11kw 470rpm), DLZF-24(7.5kw), DLZF-24(15kw), DLZF-26
- Power Source: Electric
- Power: 11kw
- Voltage: 380 V
- Air Flow Rate: 60000~160000 m³/h
- Blade Material: Aluminum Alloy Blades
Technical Specifications
| Voltage | 380 V |
|---|---|
| Type | Axial Fan |
| Blade Material | Aluminum Alloy Blades |
| Mounting Type | Other |
| Bearing Type | Cylindrical Roller Bearing |
| Power Source | Electric |
| Warranty | 1 Year |
| After-Sales Service Provided | Online support |
| Place Of Origin | Jiangsu, China |
| Brand Name | MINXIN |
| Model Number | DLZF-18, DLZF-22(7.5kw), DLZF-22(11kw 580rpm), DLZF-22(11kw 470rpm), DLZF-24(7.5kw), DLZF-24(15kw), DLZF-26 |
| Product Name | Axial Cooling Fan |
| Model | DLZF-22 |
| Power | 11kw |
| Air Flow Rate | 60000~160000 m³/h |
| Total Pressure | 140~250 Pa |
| Noise | 80dB(A) |
| Speed | 470rpm |
| Stage | 12 |
| Selling Units | Single item |
| Single Package Size | 300X300X100 cm |
| Single Gross Weight | 500.0 kg |
Product Details


Product Name | Axial Cooling Fan |
Blade Material | Aluminum Alloy Blades |
Model | DLZF-18, DLZF-22, DLZF-24, DLZF-26 |












Ordering Instructions
Usage Instructions
2.1 After the fan has been running for the first 48 hours, stop the machine and check whether the fasteners of all fan components are loose. If any looseness is detected, retighten them.
2.2 The working site where the fan operates should be kept clean to prevent debris from being sucked into the fan and damaging the blades.
2.3 Regularly remove the dirt on the surface of the blades and check for any damage to the blades.
2.4 Add No. 3 lithium – base grease to the belt reducer every three months. For the gear reducer, replenish the gear oil every month and replace it every six months. (When the ambient temperature is below – 15°C, low – temperature grease or low – temperature lubricating oil should be used.)
2.5 Regularly adjust the tension of the drive belt, and check its degree of wear and aging. Replace it if the situation is severe.
2.6 If the fan is out of service for less than two months, the drive belt should be kept loose. If the planned downtime is more than two months, remove the drive belt and store it in the warehouse.
3.1 Operation Process for Belt Replacement:
3.1.1 Before operation, make sure your clothing is appropriate to avoid hair, gloves, clothes, etc. from being caught in rotating components such as belt pulleys.
3.1.2 Confirm that the power supply has been cut off, rotating components like pulleys have stopped rotating, and there are protective covers around the pulleys.
3.1.4 Put on the new belt that needs to be replaced. When replacing the new belt, confirm the following points: Confirm that the specifications of the new belt are the same as those of the old belt. Select belts with the same single – belt length for matching use. (New and old belts cannot be used in the same set.)
3.1.5 Adjust the belt tension bolts to make the belt tensioned to an appropriate state, and then tighten the fixing bolts. Check whether each belt is fully installed in the pulley groove.
3.1.6 After installing the protective cover, start the machine for a trial run and then check whether the belt is functioning
properly. (Tighten the new belt once after it has run for 1 hour, and tighten it a second time after running for 3 to 5 hours.
Otherwise, the service life of the belt will be affected.)
4.1 Do not cut the old belt with a knife, scissors, etc. when the belt is tensioned, to avoid injury caused by the belt snapping
back.
4.2 Before installing the new belt, check whether the end faces of the two pulleys are aligned. Adjust them to an aligned state if they are not, before installing the belt.
① The maximum axial deviation between the driving shaft and the driven shaft should not exceed 0.5°.




5.1 Regularly inspect the running belt. After the machine is stopped, check whether the belt is in an appropriate tensioned state. If the belt has become loose, adjust the pulley to retighten the belt.
5.2 Regularly inspect the pulley grooves after the machine is stopped, and make sure that there is no foreign matter in the
grooves and the surfaces of the pulley grooves are smooth without roughness.




Ordering and Pricing
- Minimum order quantity: 2 set
- Ships from: China
- Customization: OEM and ODM accepted on qualifying volumes.
Frequently Asked Questions
What is the minimum order quantity for this cooling tower?
The standard minimum order quantity is 2 set. Trial orders can usually be arranged for buyers evaluating the product before a full production run.
What warranty is provided?
The manufacturer provides a 1 Year warranty. Spare parts and technical support remain available after the warranty period.
Can the cooling tower be supplied for my local voltage?
The standard configuration is 380 V. Alternative voltage and frequency builds are available when specified at the time of order.
Do you accept OEM or custom branding?
Yes. Custom logo, colour, packaging and specification changes are accepted on qualifying order volumes. Send your artwork and technical requirements with your enquiry.
How long does production and delivery take?
In-stock configurations typically ship within 7–15 days. Customised or large-volume orders are usually produced in 25–35 days, confirmed on order.
About the Manufacturer
This product is produced by Wuxi Master Cooling Machinery Manufacturing Co., Ltd., based in China. The company 5 years as a verified Alibaba.com supplier, operates its own manufacturing. Browse the full Wuxi Master Cooling Machinery Manufacturing Co., Ltd. range on HVACR Nexus.
See more in Axial Flow Fans on HVACR Nexus.