Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - view 2
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - view 3
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - view 4
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - view 5
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - view 6

Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a

$999.00

Temperature Humidity Rooftop Unit. Key specification: heating capacity 9-200, refrigerant R22/R410a. Ships factory-direct with the manufacturer’s data sheet.

Mounting Type
Wall / Window Mount
Warranty
More Than 5 Years
Place Of Origin
Zhejiang, China
Operating Voltage
AC380 3N~50Hz
Refrigerant
R22/R410a
Heating Capacity (Electric Heating/KW)
9-200
  • Reply within one working day
  • Factory-direct pricing, OEM & ODM accepted
  • Full specification and test reports supplied

Get Factory Pricing

Free quotation direct from the manufacturer — price, MOQ and lead time, usually within one working day. No account needed.

Enquiring about Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a

Temperature humidity rooftop unit — heating capacity 9-200, refrigerant R22/R410a. The complete factory specification follows. Made by Ningbo Longwell Electric Technology Co., Ltd. (8 years on the platform, factory-assessed). For a binding price and lead time, send the volume you need and where it ships to.

Key Features of This Temperature Humidity Rooftop Unit

  • Operating Voltage: AC380 3N~50Hz
  • Refrigerating Capacity(KW): 12.6-200
  • Heating Capacity (Electric Heating/KW): 9-200
  • Refrigerant: R22/R410a
  • Warranty: More Than 5 Years
  • Place Of Origin: Zhejiang, China

Technical Specifications

Type Precision Constant Temperature and Humidity Unit
Mounting Type Wall / Window Mount
Compressor Brand Performer, Sanyo, Fusheng, Copeland, Daikin, Hitachi, Bristol
Fan Motors Type Brushless
Key Selling Points With frequency conversion speed regulation function
Warranty More Than 5 Years
Machinery Test Report Provided
Video Outgoing-Inspection Provided
Core Components Pressure Vessel, Motor, Other, Bearing, Gear, PLC, Engine, Gearbox, Frequency, High heat transfer efficiency, Good heat dissipation, The compressor has strong liquid carrying capacity, High oil return capacity
Place Of Origin Zhejiang, China
Weight (Kg) 270
Brand Name LongWell
Dimension(L*W*H) customizable
Product Name Precision Constant Temperature and Humidity Unit
Operating Voltage AC380 3N~50Hz
Function Cooling+Heating
Refrigerant R22/R410a
Refrigerating Capacity(KW) 12.6-200
Heating Capacity (Electric Heating/KW) 9-200
Air Volume(M³/H) 2800-370000m³/h
Application factory, hotel, hospital, building, malls, residential communities,
Humidity Range /Sensitivity(%) Humidity control range: 45~70, sensitivity ±4
Temperature Range/Sensitivity(℃) Temperature control range: 18~25, sensitivity ±0.8
Selling Units Single item
Single Volume 0 cm³
Single Gross Weight 0.0 kg

Product Details

Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 1Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 2
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 3Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 4
Products Description
Product Name
Rooftop Air Conditioing Unit
Operating Voltage
220-240V/50Hz
Dimension(L*W*H)
Rooftop Air Conditioing Unit(Customizable)
Core Components
Pressure vessel/ Motor/PLC/Pump
Cooling capacity
21.9kw-570kw
Heating capacity
27.5KW-200kw
Keyword
Rooftop Air Conditioing Unit
Refrigerant
R410a/R22/R32/R290
Power Supply
380v/3N/50HZ
Heating method
heat pump heating / Electric heating /gas heating /Electric heating / hot water heating
Humidification method
electrode humidification / dry steam humidification / Electric humidification /High pressure micro mist humidification / Wet film humidification
Horizontal return air, horizontal air supply
side return air, end air supply; end return air, end air supply
Other air supply and return modes
side return air, bottom air supply; bottom return air, end air supply
Application
Restaurant/Hotels/sports arenas/exhibition centers/malls/machinerysteam heating
hot and cold source
Comes with hot and cold source
Model, speed, power and equipped motor
According to your requirements or help you recommend
Technical analysis
Integrated design, easy to install and maintain, suitable for installation directly on the roof of a building or on the
groundIntegrated design, easy to install and maintain, suitable for installation directly on the roof of a building or on the ground
Key technical components:High-efficiency compressor system, advanced air filtration system
Performance data report
Energy efficiency ratio(cop):2.8-3.45
cooling capacity:20kw-200kw      Heating capacity:27.5KW-200kw
Electrical appliance requirements: 380v-415v/50Hz/60Hz
Market positioning analysis
Target customer group: tailor-made customers for process refrigeration needs of commercial buildings such as shopping malls,office buildings, and production plants, cooling needs of power distribution rooms, mobile space cooling, etc.
Main application scenarios: Suitable for rapid cooling and heating needs of large spaces
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 5Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 6
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 7Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 8
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 9Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 10
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 11Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 12
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 13Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 14
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 15Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 16
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 17Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 18
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 19Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 20
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 21Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 22
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 23Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 24
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 25Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 26
Remarks:
1. Cooling condition: Outdoor ambient temperature: 35°c, indoor dry/wet bulb temperature: 26.7/19.4°C;
2. Heating condition: Outdoor dry/wet bulb temperature: 7/6°c; indoor dry/wet bulb temperature: 20/15°c.
3. Noise level: Measured in a semi-anechoic chamber, with measurement points located 1 meter in front ofthe equipment and abovethe floor (at a height of 1 meter+ equipment height)/2: 4. The above information may be subject to change due to product updates or other reasons.
Company Profile
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 27Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 28
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 29Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 30
If you need a clear version, please contact customer service to obtain it.
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 31Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 32
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 33Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 34
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 35Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 36
Customer feedback
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 37Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 38
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 39Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 40
Delivery and Packaging
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 41Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 42
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 43Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 44
Related Products
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 45Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 46
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 47Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 48
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 49Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 50
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 51Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 52
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 53Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 54
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 55Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 56
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 57Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 58
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 59Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 60
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 61Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 62
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 63Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 64
Top 10 reasons why customers choose LONGWELL:

1.LONGWELL is a professional manufacturer which is the specialist in HVACR fans, motor and components for the applications of air conditioner, air ex-changer, coolers, heaters, floor convectors, sterilization purifier, air purifiers, medical purifiers, and ventilation ,energy industry, 5G cabinet…
2.We have many authoritative international certifications .
3.Have professional sales team more than 200 person, Set up sites in many countries around the world,to help you solve the problem any time !
4.LONGWELL Promise will never release unqualified products !
5.Rich experience in different fields and word's most comprehensive fan soluions
6.Quality is life ! with strict quality control system,supervise the whole process from raw materials, production, quality inspection, packaging and delivery!
7.Born for High-Quality Breathing, LONGWELL Fans Power Your Equipment
8.LONGWELL have own delivery department, make sure fast delivery and regular feedback of production progress !
9.Professional after-sales team provides 24-hour online service !
10. we makes very quiet noise , and good air performances of fans !
Contact Us
Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 65Temperature Humidity Rooftop Unit, LONGWELL, R22/R410a - detail 66

Ordering and Pricing

  • Minimum order quantity: 1 piece
  • Volume pricing:
    • 1–1 piece: US $1299 / piece
    • 2–9 piece: US $1199 / piece
    • 10–19 piece: US $1099 / piece
    • 20+ piece: US $999 / piece
  • Ships from: China
  • Customization: OEM and ODM accepted on qualifying volumes.

Frequently Asked Questions

What is the minimum order quantity for this temperature humidity rooftop unit?

The standard minimum order quantity is 1 piece. Trial orders can usually be arranged for buyers evaluating the product before a full production run.

What warranty is provided?

The manufacturer provides a More Than 5 Years warranty. Spare parts and technical support remain available after the warranty period.

Can the temperature humidity rooftop unit be supplied for my local voltage?

The standard configuration is AC380 3N~50Hz. Alternative voltage and frequency builds are available when specified at the time of order.

Do you accept OEM or custom branding?

Yes. Custom logo, colour, packaging and specification changes are accepted on qualifying order volumes. Send your artwork and technical requirements with your enquiry.

How long does production and delivery take?

In-stock configurations typically ship within 7–15 days. Customised or large-volume orders are usually produced in 25–35 days, confirmed on order.

About the Manufacturer

This product is produced by Ningbo Longwell Electric Technology Co., Ltd., based in China. The company 8 years as a verified Alibaba.com supplier, Trading Company, passed third-party supplier assessment. Browse the full Ningbo Longwell Electric Technology Co., Ltd. range on HVACR Nexus.

Type

Precision Constant Temperature and Humidity Unit

Mounting Type

Wall / Window Mount

Compressor Brand

Performer, Sanyo, Fusheng, Copeland, Daikin, Hitachi, Bristol

Fan Motors Type

Brushless

Key Selling Points

With frequency conversion speed regulation function

Warranty

More Than 5 Years

Machinery Test Report

Provided

Video Outgoing-Inspection

Provided

Core Components

Pressure Vessel, Motor, Other, Bearing, Gear, PLC, Engine, Gearbox, Frequency, High heat transfer efficiency, Good heat dissipation, The compressor has strong liquid carrying capacity, High oil return capacity

Place Of Origin

Zhejiang, China

Weight (Kg)

270

Brand Name

LongWell

Dimension(L*W*H)

customizable

Product Name

Precision Constant Temperature and Humidity Unit

Operating Voltage

AC380 3N~50Hz

Function

Cooling+Heating

Refrigerant

R22/R410a

Refrigerating Capacity(KW)

12.6-200

Heating Capacity (Electric Heating/KW)

9-200

Air Volume(M³/H)

2800-370000m³/h

Application

factory, hotel, hospital, building, malls, residential communities,

Humidity Range /Sensitivity(%)

Humidity control range: 45~70, sensitivity ±4

Temperature Range/Sensitivity(℃)

Temperature control range: 18~25, sensitivity ±0.8

Selling Units

Single item

Single Volume

0 cm³

Single Gross Weight

0.0 kg

More from Ningbo Longwell Electric Technology Co., Ltd.

Other equipment from the same manufacturer — one enquiry can cover several items.

Compare Other Rooftop Units

Alternatives in the same category, from different verified suppliers.

Explore related

Specifications, certifications and images on this page are as published by the manufacturer and have not been independently tested or verified by HVACR Nexus. Confirm the full specification and the approvals valid in your market in writing before ordering. Content & IP notice