Air Handling Unit, Ducted, 380V, 59.8 kw

$1,654.00

Air Handling Unit: 380V/3pH /50Hz, 59.8 kw. Supplied direct from the factory with the complete specification. Refrigerant: R-410A. Type: Air Handling Unit.

Type
Air Handling Unit
Refrigerant
R-410A
Warranty
1 Year
Place Of Origin
Guangdong, China
Model Number
MRDW100SS
Cooling Capacity
59.8 kw
  • Reply within one working day
  • Factory-direct pricing, OEM & ODM accepted
  • Full specification and test reports supplied

Get Factory Pricing

Price, MOQ and lead time direct from the manufacturer. Free, no account needed.

Enquiring about Air Handling Unit, Ducted, 380V, 59.8 kw

Key specification for this air handling unit: 380V/3pH /50Hz, 59.8 kw. Everything below is reproduced from the factory data sheet. Made by Shenzhen Monchrui Industry Development Co., Ltd. (9 years on the platform, typical reply ≤5h). Send your target quantity and destination for a firm quotation with current lead times.

Key Features of This Air Handling Unit

  • Model Number: MRDW100SS
  • Power Supply: 380V/3pH /50Hz
  • Cooling Capacity: 59.8 kw
  • Heating Capacity: 93.0 kw
  • Refrigerant: R-410A
  • Warranty: 1 Year

Technical Specifications

Type Air Handling Unit
Refrigerant R-410A
Mounting Type Ceiling Mount
Compressor Brand Copeland
Fan Motors Type AC
Motor Type AC Motor
Application Hotel, Mall
Key Selling Points High efficiency
Warranty 1 Year
Machinery Test Report Provided
Video Outgoing-Inspection Provided
Core Components Motor
Place Of Origin Guangdong, China
Weight (Kg) 276
Brand Name MONCHRUI
Model Number MRDW100SS
Dimension(L*W*H) 1430*1650*820mm
Product Name Jet Flow Type Double Skin Air Handling Unit
Row 3/4 Rows
Cooling Capacity 59.8 kw
Heating Capacity 93.0 kw
Feature return air jet flow
Water Flow I/S 2.84
Applicable Industries Factory hotel hospital hall
After-Sales Service Provided Free spares
After Warranty Service Online support
Power Supply 380V/3pH /50Hz
Selling Units Single item
Single Volume 0 cm³
Single Gross Weight 0.0 kg

Product Details

Product Overview
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 1Air Handling Unit, Ducted, 380V, 59.8 kw - detail 2
Products Description
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 3Air Handling Unit, Ducted, 380V, 59.8 kw - detail 4
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 5Air Handling Unit, Ducted, 380V, 59.8 kw - detail 6
Pipe orientation
When you face toward the air outlet-counter air current,connection pipes on the left are left oriented and vice versa.
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 7Air Handling Unit, Ducted, 380V, 59.8 kw - detail 8
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 9Air Handling Unit, Ducted, 380V, 59.8 kw - detail 10
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 11Air Handling Unit, Ducted, 380V, 59.8 kw - detail 12
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 13Air Handling Unit, Ducted, 380V, 59.8 kw - detail 14
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 15Air Handling Unit, Ducted, 380V, 59.8 kw - detail 16
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 17Air Handling Unit, Ducted, 380V, 59.8 kw - detail 18
Dimensions of jet air handing unit and Parameter table of jet type double skin air handing unit
Considering the full pressure of the air conditioning unit and the specification of spherical spherical nozzle,the flowing table show the range of the jet type double-skin air handing unit

Wet-film humidifier

1.Working principle of wet-film humidifier The working principle of the wet film direct drainage and humidification system:the clean tap water passing through the solenoid valve is sent to the water distributor on the top of the wet film through the water supply pipeline,and the water flows down along the surface of the wet film under the action of gravity,thereby moistening the surface of the wet film and flowing to the connection The water in the water pan is discharged into the sewer pipe through the drainage elbow,that is,the water is not recycled.When the hot air passes through the humid wet film,its humidity increases and the temperature drops.This humidification process is called an isenthalpic humidification process.In this process,part of the water on the wet film is evaporated,but no additional energy is consumed. 2.Operating conditions of wet-film humidifier Ambient temperature:the main body of the wet film is 5~100℃,the electric control box is 5~50℃.below 90%RH. Critical fan speed:3.75m/s or less. Water supply quality:tap water or the same type of water. Water supply temperature:5~40℃. Water supply pressure:0.15~0.75MPa. 3.Features of wet film humidifier There is no"white powder"phenomenon in the humidification and cooling of clean humidification and humid film. The humidification section is short and the vaporization space of the wet film humidification and cooling system is only the thickness of the wet film body. High saturation efficiency-the saturation efficiency of the wet film humidification and cooling system can be as high as 90%or more. Safe and reliable.The membrane material is anti-mold and anti-bacterial,with a life span of 5 to 8 years.There is no" water leakage"in the spray room as a whole.
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 19Air Handling Unit, Ducted, 380V, 59.8 kw - detail 20
2. Unit electrical wiring diagram(380V/3N~/50Hz)
3. Operation precautions (1) Check whether the water pipe is normal, and completely remove the gas in the pipe. (2) Check whether the air duct pipeline is normal, whether there is any blockage of foreign matter, and place the valve in the pipeline in the normal position. (3) Check the grounding resistance of the motor coil, which must be above 1.0MΩ. Power transmission and operation, check whether the three-phase current is balanced and normal. (4) Check whether the fan rotates in the reverse direction. If the direction of rotation is found to be incorrect, the phase sequence must be adjusted to correct it. 4. Precautions for maintenance (1) When the unit is not in use, the heat exchanger should be filled with water in summer to reduce pipe corrosion, and the water in the heat exchanger should be drained in winter to avoid freezing and cracking. (2) Air filter: clean before use and every month during use. (3) Heat exchange coil: the surface of the aluminum sheet and the inside of the copper tube must be cleaned once a year. (4) Drain pan: cleaned–times a year. (5) Water seal elbow: cleaned once a year
Product Paramenters
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 21Air Handling Unit, Ducted, 380V, 59.8 kw - detail 22
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 23Air Handling Unit, Ducted, 380V, 59.8 kw - detail 24
Product Images
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 25Air Handling Unit, Ducted, 380V, 59.8 kw - detail 26
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 27Air Handling Unit, Ducted, 380V, 59.8 kw - detail 28
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 29Air Handling Unit, Ducted, 380V, 59.8 kw - detail 30
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 31Air Handling Unit, Ducted, 380V, 59.8 kw - detail 32
Why Choose Us
Advanced Equipment Factory
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 33Air Handling Unit, Ducted, 380V, 59.8 kw - detail 34
Complete product certificates
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 35Air Handling Unit, Ducted, 380V, 59.8 kw - detail 36
Exhibition&Client Visits
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 37Air Handling Unit, Ducted, 380V, 59.8 kw - detail 38
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 39Air Handling Unit, Ducted, 380V, 59.8 kw - detail 40
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 41Air Handling Unit, Ducted, 380V, 59.8 kw - detail 42
Packing & Shipping
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 43Air Handling Unit, Ducted, 380V, 59.8 kw - detail 44
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 45Air Handling Unit, Ducted, 380V, 59.8 kw - detail 46
Air Handling Unit, Ducted, 380V, 59.8 kw - detail 47Air Handling Unit, Ducted, 380V, 59.8 kw - detail 48

Ordering and Pricing

  • Minimum order quantity: 5 piece
  • Volume pricing:
    • 5–9 piece: US $1737 / piece
    • 10–19 piece: US $1704 / piece
    • 20+ piece: US $1654 / piece
  • Ships from: China
  • Customization: OEM and ODM accepted on qualifying volumes.

Frequently Asked Questions

What is the minimum order quantity for this air handling unit?

The standard minimum order quantity is 5 piece. Trial orders can usually be arranged for buyers evaluating the product before a full production run.

What warranty is provided?

The manufacturer provides a 1 Year warranty. Spare parts and technical support remain available after the warranty period.

Can the air handling unit be supplied for my local voltage?

The standard configuration is 380V/3pH /50Hz. Alternative voltage and frequency builds are available when specified at the time of order.

Do you accept OEM or custom branding?

Yes. Custom logo, colour, packaging and specification changes are accepted on qualifying order volumes. Send your artwork and technical requirements with your enquiry.

How long does production and delivery take?

In-stock configurations typically ship within 7–15 days. Customised or large-volume orders are usually produced in 25–35 days, confirmed on order.

About the Manufacturer

This product is produced by Shenzhen Monchrui Industry Development Co., Ltd., based in China. The company 9 years as a verified Alibaba.com supplier, operates its own manufacturing. Browse the full Shenzhen Monchrui Industry Development Co., Ltd. range on HVACR Nexus.

Type

Air Handling Unit

Refrigerant

R-410A

Mounting Type

Ceiling Mount

Compressor Brand

Copeland

Fan Motors Type

AC

Motor Type

AC Motor

Application

Hotel, Mall

Key Selling Points

High efficiency

Warranty

1 Year

Machinery Test Report

Provided

Video Outgoing-Inspection

Provided

Core Components

Motor

Place Of Origin

Guangdong, China

Weight (Kg)

276

Brand Name

MONCHRUI

Model Number

MRDW100SS

Dimension(L*W*H)

1430*1650*820mm

Product Name

Jet Flow Type Double Skin Air Handling Unit

Row

3/4 Rows

Cooling Capacity

59.8 kw

Heating Capacity

93.0 kw

Feature

return air jet flow

Water Flow I/S

2.84

Applicable Industries

Factory hotel hospital hall

After-Sales Service Provided

Free spares

After Warranty Service

Online support

Power Supply

380V/3pH /50Hz

Selling Units

Single item

Single Volume

0 cm³

Single Gross Weight

0.0 kg

More from Shenzhen Monchrui Industry Development Co., Ltd.

Other equipment from the same manufacturer — one enquiry can cover several items.

Compare Other Air Handling Units

Alternatives in the same category, from different verified suppliers.

Explore related

Specifications, certifications and images on this page are as published by the manufacturer and have not been independently tested or verified by HVACR Nexus. Confirm the full specification and the approvals valid in your market in writing before ordering. Content & IP notice