Air Handling Unit, Ceiling, 5500 m3, R410A - view 2
Air Handling Unit, Ceiling, 5500 m3, R410A - view 3
Air Handling Unit, Ceiling, 5500 m3, R410A - view 4
Air Handling Unit, Ceiling, 5500 m3, R410A - view 5
Air Handling Unit, Ceiling, 5500 m3, R410A - view 6

Air Handling Unit, Ceiling, 5500 m3, R410A

$2,500.00

Air Handling Unit. Key specification: 5500 m3/h, refrigerant R410A. Ships factory-direct with the manufacturer’s data sheet. Type: Air Handling Unit.

Type
Air Handling Unit
Warranty
1 Year
Place Of Origin
Beijing, China
Airflow
5500 m3/h
Refrigerant
R410A
  • Reply within one working day
  • Factory-direct pricing, OEM & ODM accepted
  • Full specification and test reports supplied

Get Factory Pricing

Free quotation direct from the manufacturer — price, MOQ and lead time, usually within one working day. No account needed.

Enquiring about Air Handling Unit, Ceiling, 5500 m3, R410A

Air handling unit — 5500 m3/h, refrigerant R410A. The complete factory specification follows. Made by Guangzhou Airwoods Environment Technology Co., Ltd. (13 years on the platform, factory-assessed). For a binding price and lead time, send the volume you need and where it ships to.

Key Features of This Air Handling Unit

  • Indoor Unit Fan Power: 1.5 KW
  • Nominal Cooling Capacity: 25.5 Kw
  • Nominal Heating Capacity: 28.3 Kw
  • Airflow: 5500 m3/h
  • Refrigerant: R410A
  • Warranty: 1 Year

Technical Specifications

Type Air Handling Unit
Mounting Type Floor Standing
Compressor Brand other
Fan Motors Type AC
Application Warehouse, Office, Plant, School, Home, Hotel, Hospital
Key Selling Points Competitive Price, Eco-Friendly, Low Maintenance Cost, Easy To Operate
Warranty 1 Year
Machinery Test Report Provided
Video Outgoing-Inspection Provided
Core Components Motor, PLC, Engine
Place Of Origin Beijing, China
Weight (Kg) 755
Brand Name Holtop
Dimension(L*W*H) customized size
AHU Type DX Inverter Air Handling Unit
Airflow 5500 m3/h
Nominal Cooling Capacity 25.5 Kw
Nominal Heating Capacity 28.3 Kw
Refrigerant R410A
Indoor Unit External Pressure 150Pa
Indoor Unit Fan Type High efficient DC fan
Indoor Unit Fan Power 1.5 KW
Compressor Type DC inverter compressor
Outdoor Unit Size L*W*H 990x850x1810mm
Selling Units Single item
Single Package Size 400X250X400 cm
Single Gross Weight 1000.0 kg

Product Details

Application Scenarios
It is for industrial air condition control field like humidity, cleanliness, fresh air exchange, noise, toxic and harmful gas control, with requirements on energy saving and environmental protection.
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 1Air Handling Unit, Ceiling, 5500 m3, R410A - detail 2
Product Structure
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 3Air Handling Unit, Ceiling, 5500 m3, R410A - detail 4
Cooling coil/humidifier valves
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 5Air Handling Unit, Ceiling, 5500 m3, R410A - detail 6
Natural gas heating system
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 7Air Handling Unit, Ceiling, 5500 m3, R410A - detail 8
2mm thick steel frame
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 9Air Handling Unit, Ceiling, 5500 m3, R410A - detail 10
Rock wool insulation
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 11Air Handling Unit, Ceiling, 5500 m3, R410A - detail 12
Service ladder
Spare Parts Section
FILTER SECTION
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 13Air Handling Unit, Ceiling, 5500 m3, R410A - detail 14
Metal mesh filter
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 15Air Handling Unit, Ceiling, 5500 m3, R410A - detail 16
Auto-rolling filter
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 17Air Handling Unit, Ceiling, 5500 m3, R410A - detail 18
Chemical filter
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 19Air Handling Unit, Ceiling, 5500 m3, R410A - detail 20
Self-cleaning and high-efficiency cartridge filter
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 21Air Handling Unit, Ceiling, 5500 m3, R410A - detail 22
Paintmist filter
GAS HEATING SECTION
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 23Air Handling Unit, Ceiling, 5500 m3, R410A - detail 24

Gas direct combustion heating

1.There is no need to provide additional combustionsupporting air. When the inlet air passes through the mixing plate of the burner, it is fully mixed with the gas injected from the collector pipe of the burner to achieve clean combustion. 2.The adjustment ratio can reach 30:1, which effectively meets the strict requirements on temperature control accuracy and a wider range of applicability. 3.The emission standards of NOX, CO and other harmful gases after combustion fully meet the requirements of the latest emission standards of the US Environmental ProtectionAgency in 2002. 4.Design and manufacture of combustion system complies to European EN746 standard. 5.Gas direct combustion heater safety combustion temperature control system and safety protection devices include: safety interlock detection, automatic purging, automatically ignite low flame, full flame monitoring, automatically transfer to large fire, proportional combustion, constant temperature control, and fault cut-off alarm.
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 25Air Handling Unit, Ceiling, 5500 m3, R410A - detail 26

Gas indirect combustion heating

It is mainly composed of burner, heat exchanger, exhaust machine, electrical control and other parts, combustion air under ordinary atmospheric pressure can directly participate in the combustion process, no need compression, which is suitable for indoor and outdoor AHU. Combustion air can be taken from the indoor space where the unit is located, or introduced from outdoor, and the flue gas is exhausted to outdoor. When the air to be heated passes through the outer surface of the high-temperature heat exchanger, it conducts indirect heat exchange with the high-temperature flue gas produced by the combustion of natural gas.
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 27Air Handling Unit, Ceiling, 5500 m3, R410A - detail 28
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 29Air Handling Unit, Ceiling, 5500 m3, R410A - detail 30

HUMIDIFIER SECTION

Traditional humidification type Constant enthalpy humidification: spray humidification, spray humidification, wet film humidification, ultrasonic humidification Isothermal humidification: dry steam humidification, electrode humidification, electric heating humidification For different environments, we have different humidification methods, but the most frequently used one is the wet film humidification.
Spray humidification 1.High-pressure spray system is adopted in the humidification section of the fresh air handling unit in the spray booth and the air supply air handling unit in the clean room. It mainly includes circulating water pump, pipeline system, stainless steel nozzle, water tank, water tank makeup and drainage system, air equalizing plate, aluminum alloy water baffle, liquid level gauge, humidity detection element and electric control system, other pipelines and valves, etc. 2.The spray circulation pipeline is made of SS304 stainless steel, the globe valve, non-return valve, pressure gauge, flange, elbow and other accessories are all made of SS304 stainless steel, the nozzles are arranged in double rows, and the circulating water tank is made of SS304 stainless steel (3mm thick). Equipped with water inlet solenoid valve, liquid level sensor and drainage solenoid valve, automatic water replenishment can be realized. All materials are made of SS304 stainless steel. The bottom of the water tank must have a certain inclination angle to facilitate tilting the water tank. 3.The humidification section is equipped with an electronic control system for automatic humidity control, showing the measured value. Through various electrical interfaces to achieve humidity sensor, controller, inverter, liquid level sensor, pump station system communication and control, and the internal program to achieve humidification control.
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 31Air Handling Unit, Ceiling, 5500 m3, R410A - detail 32
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 33Air Handling Unit, Ceiling, 5500 m3, R410A - detail 34
AHU internal spray system Air handling Unit
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 35Air Handling Unit, Ceiling, 5500 m3, R410A - detail 36
Spray valve group
FAN SECTION
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 37Air Handling Unit, Ceiling, 5500 m3, R410A - detail 38
Double inlet belt-drive fan
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 39Air Handling Unit, Ceiling, 5500 m3, R410A - detail 40
Plug fan
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 41Air Handling Unit, Ceiling, 5500 m3, R410A - detail 42
EC plug fan
Functional Sections Diagram
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 43Air Handling Unit, Ceiling, 5500 m3, R410A - detail 44
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 45Air Handling Unit, Ceiling, 5500 m3, R410A - detail 46
Control System
Constant temperature and humidity solutions The automatic control system of Holtop combined air handling unit realizes the simplification of professional ventilation or air system regulation. The best air conditioning control scheme is achieved by using three control strategies: annual multi-condition energy saving control, supply air state control for cooling/heat comfort of human body or specific process requirements, and on-line energy saving control of air conditioning and chillers or building control systems.
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 47Air Handling Unit, Ceiling, 5500 m3, R410A - detail 48
Our service

What we can do for you?

1) We produce high quality AHU based on clients' need and help clients doing project design.
2) We offer a package(turn-key) service including engineering, design, installation, aftersale service,etc.
3) We are especially professionl and strong in cleanroom HVAC engineering.

What kind of HVAC job that we can do?

1) Food, Eectronic, Textile, Tobacco Industry, Hotels, Office, Sports Center, Exhibition center, etc.

Air Handling Unit, Ceiling, 5500 m3, R410A - detail 49Air Handling Unit, Ceiling, 5500 m3, R410A - detail 50
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 51Air Handling Unit, Ceiling, 5500 m3, R410A - detail 52
Company Introduction
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 53Air Handling Unit, Ceiling, 5500 m3, R410A - detail 54
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 55Air Handling Unit, Ceiling, 5500 m3, R410A - detail 56
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 57Air Handling Unit, Ceiling, 5500 m3, R410A - detail 58
Air Handling Unit, Ceiling, 5500 m3, R410A - detail 59Air Handling Unit, Ceiling, 5500 m3, R410A - detail 60
Hot sale products

Ordering and Pricing

  • Minimum order quantity: 1 unit
  • Volume pricing:
    • 1–999 unit: US $3000 / unit
    • 1000+ unit: US $2500 / unit
  • Ships from: China
  • Customization: OEM and ODM accepted on qualifying volumes.

Frequently Asked Questions

What is the minimum order quantity for this air handling unit?

The standard minimum order quantity is 1 unit. Trial orders can usually be arranged for buyers evaluating the product before a full production run.

What warranty is provided?

The manufacturer provides a 1 Year warranty. Spare parts and technical support remain available after the warranty period.

Do you accept OEM or custom branding?

Yes. Custom logo, colour, packaging and specification changes are accepted on qualifying order volumes. Send your artwork and technical requirements with your enquiry.

How long does production and delivery take?

In-stock configurations typically ship within 7–15 days. Customised or large-volume orders are usually produced in 25–35 days, confirmed on order.

About the Manufacturer

This product is produced by Guangzhou Airwoods Environment Technology Co., Ltd., based in China. The company 13 years as a verified Alibaba.com supplier, operates its own manufacturing, passed third-party supplier assessment. Browse the full Guangzhou Airwoods Environment Technology Co., Ltd. range on HVACR Nexus.

Type

Air Handling Unit

Mounting Type

Floor Standing

Compressor Brand

other

Fan Motors Type

AC

Application

Warehouse, Office, Plant, School, Home, Hotel, Hospital

Key Selling Points

Competitive Price, Eco-Friendly, Low Maintenance Cost, Easy To Operate

Warranty

1 Year

Machinery Test Report

Provided

Video Outgoing-Inspection

Provided

Core Components

Motor, PLC, Engine

Place Of Origin

Beijing, China

Weight (Kg)

755

Brand Name

Holtop

Dimension(L*W*H)

customized size

AHU Type

DX Inverter Air Handling Unit

Airflow

5500 m3/h

Nominal Cooling Capacity

25.5 Kw

Nominal Heating Capacity

28.3 Kw

Refrigerant

R410A

Indoor Unit External Pressure

150Pa

Indoor Unit Fan Type

High efficient DC fan

Indoor Unit Fan Power

1.5 KW

Compressor Type

DC inverter compressor

Outdoor Unit Size L*W*H

990x850x1810mm

Selling Units

Single item

Single Package Size

400X250X400 cm

Single Gross Weight

1000.0 kg

More from Guangzhou Airwoods Environment Technology Co., Ltd.

Other equipment from the same manufacturer — one enquiry can cover several items.

Compare Other Air Handling Units

Alternatives in the same category, from different verified suppliers.

Explore related

Specifications, certifications and images on this page are as published by the manufacturer and have not been independently tested or verified by HVACR Nexus. Confirm the full specification and the approvals valid in your market in writing before ordering. Content & IP notice