Air Handling Unit, 5500m3, R410A - view 2
Air Handling Unit, 5500m3, R410A - view 3
Air Handling Unit, 5500m3, R410A - view 4
Air Handling Unit, 5500m3, R410A - view 5
Air Handling Unit, 5500m3, R410A - view 6

Air Handling Unit, 5500m3, R410A, Floor Standing, 25.5 Kw

$2,500.00

Air Handling Unit — 5500m3/h, refrigerant R410A. Factory-direct from a verified manufacturer, full specification published. Type: Air Handling Unit.

Type
Air Handling Unit
Airflow
5500m3/h
Operating Voltage
380/400 VAC
Warranty
1 Year
Place Of Origin
Beijing, China
Refrigerant
R410A
  • Reply within one working day
  • Factory-direct pricing, OEM & ODM accepted
  • Full specification and test reports supplied

Get Factory Pricing

Price, MOQ and lead time direct from the manufacturer. Free, no account needed.

Enquiring about Air Handling Unit, 5500m3, R410A, Floor Standing, 25.5 Kw

This air handling unit is published with the manufacturer’s full specification — 5500m3/h, refrigerant R410A. Made by Guangzhou Airwoods Environment Technology Co., Ltd. (13 years on the platform, factory-assessed). Send your target quantity and destination for a firm quotation with current lead times.

Key Features of This Air Handling Unit

  • Indoor Unit Fan Power: 1.5 KW
  • Operating Voltage: 380/400 VAC
  • Nominal Cooling Capacity: 25.5 Kw
  • Nominal Heating Capacity: 28.3 Kw
  • Airflow: 5500m3/h
  • Refrigerant: R410A

Technical Specifications

Type Air Handling Unit
Airflow 5500m3/h
Operating Voltage 380/400 VAC
Mounting Type Floor Standing
Key Selling Points Competitive Price
Warranty 1 Year
Machinery Test Report Provided
Video Outgoing-Inspection Provided
Core Components Motor, PLC, Engine
Place Of Origin Beijing, China
Weight (Kg) 755 KG
Brand Name Holtop
Dimension(L*W*H) customized size
AHU Type DX Inverter Air Handling Unit
Nominal Cooling Capacity 25.5 Kw
Nominal Heating Capacity 28.3 Kw
Refrigerant R410A
Indoor Unit External Pressure 150Pa
Indoor Unit Fan Type High efficient DC fan
Indoor Unit Fan Power 1.5 KW
Compressor Type DC inverter compressor
Outdoor Unit Size L*W*H 990x850x1810mm
Selling Units Single item
Single Package Size 400X250X400 cm
Single Gross Weight 1000.000 kg

Product Details

Projects Cases
Air Handling Unit, 5500m3, R410A - detail 1Air Handling Unit, 5500m3, R410A - detail 2
Air Handling Unit, 5500m3, R410A - detail 3Air Handling Unit, 5500m3, R410A - detail 4
Air Handling Unit, 5500m3, R410A - detail 5Air Handling Unit, 5500m3, R410A - detail 6
Air Handling Unit, 5500m3, R410A - detail 7Air Handling Unit, 5500m3, R410A - detail 8
Air Handling Unit, 5500m3, R410A - detail 9Air Handling Unit, 5500m3, R410A - detail 10
Air Handling Unit, 5500m3, R410A - detail 11Air Handling Unit, 5500m3, R410A - detail 12
Air Handling Unit, 5500m3, R410A - detail 13Air Handling Unit, 5500m3, R410A - detail 14
Air Handling Unit, 5500m3, R410A - detail 15Air Handling Unit, 5500m3, R410A - detail 16
Air Handling Unit, 5500m3, R410A - detail 17Air Handling Unit, 5500m3, R410A - detail 18
Air Handling Unit, 5500m3, R410A - detail 19Air Handling Unit, 5500m3, R410A - detail 20
Product description

We are BAQ (Building Air Quality)Integrated Solutioner Specialist
Mainly cover below sectors:
Turn-Key Engineering Project
Building HVAC solution (residential & commercial)
Manufacturing Process HVAC Solution
Clean Room Solution (electric, food process, laboratory, etc.)
VOCs Solution (volatile organic compounds)
Modern Agriculture (Mushroom, Hatchery, etc.)

Product name
Air handling unit
Material
Steel
Function
Heat recovery,adjust cold/heat/humidity
Application
Home,office,factory,plaza,toilets and other house
Filter class
G4+F7+H10
Place of origin
Beijing,China
STRUCTURAL FEATURES OF THE TOP DISCHARGE OUTDOOR UNIT
Air Handling Unit, 5500m3, R410A - detail 21Air Handling Unit, 5500m3, R410A - detail 22
Air Handling Unit, 5500m3, R410A - detail 23Air Handling Unit, 5500m3, R410A - detail 24

Air Handling Units AHU

Air handling units’ condition and distribute air within a building. They take fresh ambient air from outside, clean it, heat it or cool it, maybe humidify it and then force it through some ductwork around to the designed areas within a building.

We preserve increasing and perfecting our solutions and service. At the same time, we function actively to do research and growth for OEM Customized Air Handling Unit Ventilation. ahu recuperator. ahu air handling unit

Air Handling Unit, 5500m3, R410A - detail 25Air Handling Unit, 5500m3, R410A - detail 26

Working principle:

● Both supply fan and exhaust fan are built inside to bring in fresh air and exhaust out the stale indoor air as well, thus to keep indoor space in natural comfort.
● Built-in heat exchanger (rotary heat exchanger or
plate heat exchanger) transfers energy contained in
the outgoing indoor air to the coming fresh air, thus fresh air is precooled or preheated.
● Various functional sections such as filter section, cooling/heating section, humidifying section etc. can be combined together to meet different air treatment requirements.

Air Handling Unit, 5500m3, R410A - detail 27Air Handling Unit, 5500m3, R410A - detail 28

Main Combination:

Combination mode 1: Wheel + Coarse filter (medium filter) + Cooling coil (heating coil+ Humidification + Fan)

Air Handling Unit, 5500m3, R410A - detail 29Air Handling Unit, 5500m3, R410A - detail 30

Main Combination:

Combination mode 2: Plate heat exchanger + Coarse filter (medium filter) + Mixed air +Cooling coil (heating coil + Fan )

Air Handling Unit, 5500m3, R410A - detail 31Air Handling Unit, 5500m3, R410A - detail 32


Air handling units
with heat recovery core

Air handling units
with heat recovery rotary wheel
Air Handling Unit, 5500m3, R410A - detail 33Air Handling Unit, 5500m3, R410A - detail 34
Air Handling Unit, 5500m3, R410A - detail 35Air Handling Unit, 5500m3, R410A - detail 36


FAN SECTION

We offer different types of fans such as direct driven centrifugal fan, belt driven DIDW forward centrifugal fan, and belt driven DIDW backward centrifugal fan etc..

Air Handling Unit, 5500m3, R410A - detail 37Air Handling Unit, 5500m3, R410A - detail 38

Air filter

In order to ensure heat exchanging efficiency and cleanness, combination of G3 coarse filter and F5 medium filter is selected as standard configuration in HJK AHU.

Air Handling Unit, 5500m3, R410A - detail 39Air Handling Unit, 5500m3, R410A - detail 40

Heat Exchangers

Crossflow total heat exchanger, cross-flow plate heat exchanger, or rotary heat exchanger to meet different demands.
Air Handling Unit, 5500m3, R410A - detail 41Air Handling Unit, 5500m3, R410A - detail 42
Our service

What we can do for you?

1) We produce high quality AHU based on clients' need and help clients doing project design.
2) We offer a package(turn-key) service including engineering, design, installation, aftersale service,etc.
3) We are especially professionl and strong in cleanroom HVAC engineering.

What kind of HVAC job that we can do?

1) Food, Eectronic, Textile, Tobacco Industry, Hotels, Office, Sports Center, Exhibition center, etc.

Air Handling Unit, 5500m3, R410A - detail 43Air Handling Unit, 5500m3, R410A - detail 44
Air Handling Unit, 5500m3, R410A - detail 45Air Handling Unit, 5500m3, R410A - detail 46

Industrial air handling units project reference

Company Introduction
Air Handling Unit, 5500m3, R410A - detail 47Air Handling Unit, 5500m3, R410A - detail 48
Air Handling Unit, 5500m3, R410A - detail 49Air Handling Unit, 5500m3, R410A - detail 50
Air Handling Unit, 5500m3, R410A - detail 51Air Handling Unit, 5500m3, R410A - detail 52
Air Handling Unit, 5500m3, R410A - detail 53Air Handling Unit, 5500m3, R410A - detail 54
Hot sale products

Ordering and Pricing

  • Minimum order quantity: 1 unit
  • Volume pricing:
    • 1–999 unit: US $3000 / unit
    • 1000+ unit: US $2500 / unit
  • Ships from: China
  • Customization: OEM and ODM accepted on qualifying volumes.

Frequently Asked Questions

What is the minimum order quantity for this air handling unit?

The standard minimum order quantity is 1 unit. Trial orders can usually be arranged for buyers evaluating the product before a full production run.

What warranty is provided?

The manufacturer provides a 1 Year warranty. Spare parts and technical support remain available after the warranty period.

Can the air handling unit be supplied for my local voltage?

The standard configuration is 380/400 VAC. Alternative voltage and frequency builds are available when specified at the time of order.

Do you accept OEM or custom branding?

Yes. Custom logo, colour, packaging and specification changes are accepted on qualifying order volumes. Send your artwork and technical requirements with your enquiry.

How long does production and delivery take?

In-stock configurations typically ship within 7–15 days. Customised or large-volume orders are usually produced in 25–35 days, confirmed on order.

About the Manufacturer

This product is produced by Guangzhou Airwoods Environment Technology Co., Ltd., based in China. The company 13 years as a verified Alibaba.com supplier, operates its own manufacturing, passed third-party supplier assessment. Browse the full Guangzhou Airwoods Environment Technology Co., Ltd. range on HVACR Nexus.

Type

Air Handling Unit

Airflow

5500m3/h

Operating Voltage

380/400 VAC

Mounting Type

Floor Standing

Key Selling Points

Competitive Price

Warranty

1 Year

Machinery Test Report

Provided

Video Outgoing-Inspection

Provided

Core Components

Motor, PLC, Engine

Place Of Origin

Beijing, China

Weight (Kg)

755 KG

Brand Name

Holtop

Dimension(L*W*H)

customized size

AHU Type

DX Inverter Air Handling Unit

Nominal Cooling Capacity

25.5 Kw

Nominal Heating Capacity

28.3 Kw

Refrigerant

R410A

Indoor Unit External Pressure

150Pa

Indoor Unit Fan Type

High efficient DC fan

Indoor Unit Fan Power

1.5 KW

Compressor Type

DC inverter compressor

Outdoor Unit Size L*W*H

990x850x1810mm

Selling Units

Single item

Single Package Size

400X250X400 cm

Single Gross Weight

1000.000 kg

More from Guangzhou Airwoods Environment Technology Co., Ltd.

Other equipment from the same manufacturer — one enquiry can cover several items.

Compare Other Air Handling Units

Alternatives in the same category, from different verified suppliers.

Explore related

Specifications, certifications and images on this page are as published by the manufacturer and have not been independently tested or verified by HVACR Nexus. Confirm the full specification and the approvals valid in your market in writing before ordering. Content & IP notice