Cooling Tower, PVC, HVAC

$1.50

Cooling Tower. Key specification: material PVC. Ships factory-direct with the manufacturer’s data sheet.

Material
PVC
Warranty
1 Year
Place Of Origin
Hebei, China
  • Reply within one working day
  • Factory-direct pricing, OEM & ODM accepted
  • Full specification and test reports supplied

Get Factory Pricing

Price, MOQ and lead time direct from the manufacturer. Free, no account needed.

Enquiring about Cooling Tower, PVC, HVAC

Cooling tower — material PVC. The complete factory specification follows. Made by Hengshui Nuokon Technology Co., Ltd. (2 years on the platform, typical reply ≤2h). For a binding price and lead time, send the volume you need and where it ships to.

Key Features of This Cooling Tower

  • Power(W): /
  • Voltage: /
  • Material: PVC
  • Noise Level: /
  • Warranty: 1 Year
  • Place Of Origin: Hebei, China

Technical Specifications

Voltage /
Cooling Type counter flow/cross flow
Power(W) /
Material PVC
Core Components /
Machinery Test Report Provided
Warranty 1 Year
Video Outgoing-Inspection Provided
Control Method /
Noise Level /
Key Selling Points Competitive Price
Place Of Origin Hebei, China
Weight (Kg) 0.9
Brand Name Nuokon
Dimension(L*W*H) Width 750mm*400 /800/any Length
Name cooling tower filler
Other Name cooling tower fill
Color Black,Gtey
Thickness 0.25-0.6mm
Width 950mm, 750mm
Pitch 20mm
Application Temperature -20 ℃ to +80℃
Feature High strength, anti corrosion, anti aging
Application cooling tower/Water Treament/ square/round cooling tower
After-Sales Service Provided Online
Selling Units Single item
Single Package Size 100X100X10 cm
Single Gross Weight 2.85 kg

Product Details

Product Description
High-Efficiency PVC Cooling Tower Fill Media HVAC Cooling Tower Fill for Industrial Circulating Water Cooling
Cooling Tower, PVC, HVAC - detail 1Cooling Tower, PVC, HVAC - detail 2

PVC fillings are vacuum-formed and glued together on nipple ends so that there is adequate space to avoid scaling and clogging. Thus, the water can be evenly distributed to insure good heat exchanging of cooling towers. Each layer of filling block has steel supporters to prevent from deforming and falling off. The bottom are designed with suspened supporters to avoid depositing various objects and scaling so that cooling towers can be ease of maintenance and cleaning.
Specification
cooling tower infill is an essential part of the cooling tower,application for water treatment .
The cooling tower filler quality has direct impact on the industrial cooling tower effect.
The cooling tower is one of the widely used fillers .
Cooling Tower, PVC, HVAC - detail 3Cooling Tower, PVC, HVAC - detail 4
Cooling Tower Fill Size (mm)
Fluted Size (mm)
Fill Material
Thickness (mm)
Feed Water Temperature
750mm*400mm
750mm*800mm
950mm*800mm
950mm*1200mm
950mm*1600mm


20mm


PVC, PP, CPVC


0.27-0.4 mm
PVC can reach the highest 68℃;
If the water temperature is higher than 70℃,
it needs PP material
Cooling Tower, PVC, HVAC - detail 5Cooling Tower, PVC, HVAC - detail 6
Cooling tower fill is one of the most important components for exchange of gas and water in cooling tower. It is the major parts to improve the efficiency of cooling tower and make sure the economy and safe operation. With the development of the plastic industry, counter current tower drench water plastic packing "S" shape ladder wave, obliquely wave, which has the heat dissipation, good performance, ventilated small resistance, durable, based on the easy and other advantages, it is widely used in different types of large, medium, small cooling tower.
cooling tower pvc fill
Cooling Tower, PVC, HVAC - detail 7Cooling Tower, PVC, HVAC - detail 8
Cooling Tower, PVC, HVAC - detail 9Cooling Tower, PVC, HVAC - detail 10
Cooling Tower, PVC, HVAC - detail 11Cooling Tower, PVC, HVAC - detail 12
Cooling Tower, PVC, HVAC - detail 13Cooling Tower, PVC, HVAC - detail 14
Features
1, Good raw material of 100% new PVC.
2, Proper glue point for you to install the cooling tower fill in block easily.
3, Size can be cut by customer or we cut the stipulated size for customer
4, Loose sheet can be loaded in the container with less space.
5, Installation guidance.

Matters needing attention

In order to save the shipping cost, we advise to glue the fills in customer’s site. When it finished gluing, customers can cut
their certain block size to suit for their square brand cooling tower. Please pay more attention to the following things in the
gluing:

* Please do not expose the PVC fill under the strong sunshine to avoid any deformed. If the outside temperature is higher than 40 degree, the PVC film fill will be deformed within 1-2 hours under the strong sunshine. No matter it is 100% new PVC or recycle PVC, the strong sunshine will deform it very fast.
* Please do not use the airtight or air impermeability material packing the PVC fill, such as the transparent plastic film or
bubble plastic film. That will keep the PVC fill in a higher temperature without any cool air come in and may bring some deformed.
* Please do not use the PVC cooling tower fill if the water temperature is more than 60 degree.
our work shop
Cooling Tower, PVC, HVAC - detail 15Cooling Tower, PVC, HVAC - detail 16
Cooling Tower, PVC, HVAC - detail 17Cooling Tower, PVC, HVAC - detail 18
Cooling Tower, PVC, HVAC - detail 19Cooling Tower, PVC, HVAC - detail 20
Cooling Tower, PVC, HVAC - detail 21Cooling Tower, PVC, HVAC - detail 22
Packing & Delivery
Cooling Tower, PVC, HVAC - detail 23Cooling Tower, PVC, HVAC - detail 24
Cooling Tower, PVC, HVAC - detail 25Cooling Tower, PVC, HVAC - detail 26
Cooling Tower, PVC, HVAC - detail 27Cooling Tower, PVC, HVAC - detail 28
Customized promotional fills, PVC infill for cooling Tower, competitive price cooling tower fill packing by bundle, pallet or
wooden case
Company Profile
Cooling Tower, PVC, HVAC - detail 29Cooling Tower, PVC, HVAC - detail 30
Service
1.Provide technical drawings , instructions and on-site guidance.
2.Quality guarantee is 12 months.
3.If it was proved due to the quality problem,we will make a posive response in 24 hours.
4.before shipment ,strict product and packing test.
5.OEM we can produce as the customers' sample and requirement.

Ordering and Pricing

  • Minimum order quantity: 500 piece
  • Volume pricing:
    • 500–999 piece: US $3.5 / piece
    • 1000–4999 piece: US $2.5 / piece
    • 5000+ piece: US $1.5 / piece
  • Ships from: China
  • Customization: OEM and ODM accepted on qualifying volumes.

Frequently Asked Questions

What is the minimum order quantity for this cooling tower?

The standard minimum order quantity is 500 piece. Trial orders can usually be arranged for buyers evaluating the product before a full production run.

What warranty is provided?

The manufacturer provides a 1 Year warranty. Spare parts and technical support remain available after the warranty period.

Can the cooling tower be supplied for my local voltage?

The standard configuration is /. Alternative voltage and frequency builds are available when specified at the time of order.

Do you accept OEM or custom branding?

Yes. Custom logo, colour, packaging and specification changes are accepted on qualifying order volumes. Send your artwork and technical requirements with your enquiry.

How long does production and delivery take?

In-stock configurations typically ship within 7–15 days. Customised or large-volume orders are usually produced in 25–35 days, confirmed on order.

About the Manufacturer

This product is produced by Hengshui Nuokon Technology Co., Ltd., based in China. The company 2 years as a verified Alibaba.com supplier, operates its own manufacturing. Browse the full Hengshui Nuokon Technology Co., Ltd. range on HVACR Nexus.

Voltage

/

Cooling Type

counter flow/cross flow

Power(W)

/

Material

PVC

Core Components

/

Machinery Test Report

Provided

Warranty

1 Year

Video Outgoing-Inspection

Provided

Control Method

/

Noise Level

/

Key Selling Points

Competitive Price

Place Of Origin

Hebei, China

Weight (Kg)

0.9

Brand Name

Nuokon

Dimension(L*W*H)

Width 750mm*400 /800/any Length

Name

cooling tower filler

Other Name

cooling tower fill

Color

Black,Gtey

Thickness

0.25-0.6mm

Width

950mm, 750mm

Pitch

20mm

Application Temperature

-20 ℃ to +80℃

Feature

High strength, anti corrosion, anti aging

Application

cooling tower/Water Treament/ square/round cooling tower

After-Sales Service Provided

Online

Selling Units

Single item

Single Package Size

100X100X10 cm

Single Gross Weight

2.85 kg

More from Hengshui Nuokon Technology Co., Ltd.

Other equipment from the same manufacturer — one enquiry can cover several items.

Compare Other Cooling Towers

Alternatives in the same category, from different verified suppliers.

Explore related

Specifications, certifications and images on this page are as published by the manufacturer and have not been independently tested or verified by HVACR Nexus. Confirm the full specification and the approvals valid in your market in writing before ordering. Content & IP notice