Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - view 2
Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - view 3
Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - view 4
Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - view 5
Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - view 6

Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase

$1,618.00

Fiber Laser Water Chiller. Key specification: 380 V, 220 V, 110 V, 3HP, refrigerant R-410A. Ships factory-direct with the manufacturer’s data sheet. Model Number: JLFL-6000 (Dual In / Dual Out).

Voltage
380 V, 220 V, 110 V, 3HP
Refrigerant
R-410A
Warranty
2 Years
Model Number
JLFL-6000 (Dual In / Dual Out)
Place Of Origin
Guangdong, China
Working Temperature Range
5-35℃
  • Reply within one working day
  • Factory-direct pricing, OEM & ODM accepted
  • Full specification and test reports supplied

Get Factory Pricing

Price, MOQ and lead time direct from the manufacturer. Free, no account needed.

Enquiring about Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase

Fiber laser water chiller — 380 V, 220 V, 110 V, 3HP, refrigerant R-410A. The complete factory specification follows. Made by Dongguan Blue Penguin Mechanical and Electrical Equipment Co., Ltd. (2 years on the platform, typical reply ≤2h). Send your target quantity and destination for a firm quotation with current lead times.

Key Features of This Fiber Laser Water Chiller

  • Model Number: JLFL-6000 (Dual In / Dual Out)
  • Power: 3 kW, 750 W, 0.75 kW, 4 kW, 500 W, 1.35KW, 1200 W, 5050W
  • Voltage: 380 V, 220 V, 110 V, 3HP
  • Refrigerant: R-410A
  • Warranty: 2 Years
  • Place Of Origin: Guangdong, China

Technical Specifications

Voltage 380 V, 220 V, 110 V, 3HP
Power 3 kW, 750 W, 0.75 kW, 4 kW, 500 W, 1.35KW, 1200 W, 5050W
Refrigerant R-410A
Pump Type Vane Pump
Warranty 2 Years
Machinery Test Report Provided
Video Outgoing-Inspection Provided
Key Selling Points Easy To Operate, Accurate Temperature Control, High-Accuracy, Automatic, High Productivity, Eco-Friendly, Long Service Life, Patented Product, Competitive Price
Core Components PLC, Pump, Pressure Vessel, Engine, Bearing
Container Volume 45L
Model Number JLFL-6000 (Dual In / Dual Out)
Place Of Origin Guangdong, China
Weight (Kg) 100
Brand Name Blue Penguin
Dimension(L*W*H) 750*570*1020MM
Working Temperature Range 5-35℃
Selling Units Single item
Single Volume 0 cm³
Single Gross Weight 0.0 kg

Product Details

Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 1Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 2
Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 3Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 4
Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 5Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 6
Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 7Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 8
Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 9Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 10
Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 11Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 12
Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 13Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 14
Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 15Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 16
Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 17Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 18
Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 19Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 20
Model
JLFL-6000
Working Voltage
AC 3PH 380V
Operating Current
2.7-14A
Operating Frequency
50HZ
Rated Power Input
5050W
Refrigerant
R410a
Pump Voltage/Power
220v/750W
Max. Head
47M
Max. Flow Rate
4m³/h
Inlet/Outlet Port
Rp1/2"*Rp3/4"
Cooling Water Tank Maximum Capacity
45L
Cooler Dimensions(L*W*H)
750*570*1020MM
Packaging Dimensions(L*W*H)
780*590*1160MM
Net Weight
100KG
Gross Weight
110KG
Protection Functions
Water flow protection, water temperature ultra-high alarm, water temperature ultra-lowalarm,compressor overload
protection,roomtemperature ultra-high alarm
Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 21Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 22
Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 23Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 24
Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 25Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 26
Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 27Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 28
Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 29Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 30
Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 31Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 32
Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 33Fiber Laser Water Chiller, JLFL-6000, 6kW, 380V, 3Phase - detail 34

1.Is Blue Penguin Chiller a trading company or a manufacturer?

We are both a professional trader and manufacturer of industrial chillers.

2.What type of water is recommended for use in industrial chillers?

The ideal water types are deionized water, distilled water, or purified water. These help prevent mineral buildup and corrosion inside the chiller system.

3. How often should the water in an industrial chiller be changed?

It is generally recommended to change the water every three months.
However, the frequency may vary depending on the actual operating environment. For instance, in particularly harsh conditions(e.g., dusty, high-temperature, or humid settings), changing the water monthly or even more frequently is advisable.

4.What is the ideal ambient temperature for an industrial chiller?

The chiller should operate in a well-ventilated area where the ambient temperature does not exceed 45°C (113°F). Proper
ventilation and temperature control help maintain efficiency and prevent overheating.

5. How can I prevent my chiller from freezing?

For users in high-latitude regions, especially during winter, freezing can be a common issue. To prevent this, you may install an optional heater or add an anti-freeze device to the chiller. For detailed instructions and support, please contact our customer service team.

Ordering and Pricing

  • Minimum order quantity: 1 set
  • Volume pricing:
    • 1+ set: US $1618 / set
  • Ships from: China
  • Customization: OEM and ODM accepted on qualifying volumes.

Frequently Asked Questions

What is the minimum order quantity for this fiber laser water chiller?

The standard minimum order quantity is 1 set. Trial orders can usually be arranged for buyers evaluating the product before a full production run.

What warranty is provided?

The manufacturer provides a 2 Years warranty. Spare parts and technical support remain available after the warranty period.

Can the fiber laser water chiller be supplied for my local voltage?

The standard configuration is 380 V, 220 V, 110 V, 3HP. Alternative voltage and frequency builds are available when specified at the time of order.

Do you accept OEM or custom branding?

Yes. Custom logo, colour, packaging and specification changes are accepted on qualifying order volumes. Send your artwork and technical requirements with your enquiry.

How long does production and delivery take?

In-stock configurations typically ship within 7–15 days. Customised or large-volume orders are usually produced in 25–35 days, confirmed on order.

About the Manufacturer

This product is produced by Dongguan Blue Penguin Mechanical and Electrical Equipment Co., Ltd., based in China. The company 2 years as a verified Alibaba.com supplier, operates its own manufacturing. Browse the full Dongguan Blue Penguin Mechanical and Electrical Equipment Co., Ltd. range on HVACR Nexus.

Voltage

380 V, 220 V, 110 V, 3HP

Power

3 kW, 750 W, 0.75 kW, 4 kW, 500 W, 1.35KW, 1200 W, 5050W

Refrigerant

R-410A

Pump Type

Vane Pump

Warranty

2 Years

Machinery Test Report

Provided

Video Outgoing-Inspection

Provided

Key Selling Points

Easy To Operate, Accurate Temperature Control, High-Accuracy, Automatic, High Productivity, Eco-Friendly, Long Service Life, Patented Product, Competitive Price

Core Components

PLC, Pump, Pressure Vessel, Engine, Bearing

Container Volume

45L

Model Number

JLFL-6000 (Dual In / Dual Out)

Place Of Origin

Guangdong, China

Weight (Kg)

100

Brand Name

Blue Penguin

Dimension(L*W*H)

750*570*1020MM

Working Temperature Range

5-35℃

Selling Units

Single item

Single Volume

0 cm³

Single Gross Weight

0.0 kg

More from Dongguan Blue Penguin Mechanical and Electrical Equipment Co., Ltd.

Other equipment from the same manufacturer — one enquiry can cover several items.

Compare Other Chilling Equipment

Alternatives in the same category, from different verified suppliers.

Explore related

Specifications, certifications and images on this page are as published by the manufacturer and have not been independently tested or verified by HVACR Nexus. Confirm the full specification and the approvals valid in your market in writing before ordering. Content & IP notice