Split Air Conditioners. Key specification: capacity 840,000, power type DC. Ships factory-direct with the manufacturer’s data sheet. Refrigerant: R410A. Type: Central Air Conditioners.

Type
Central Air Conditioners
Capacity (Btu)
840,000
Power Type
DC
Refrigerant
R410A
Warranty
1 Year
Place Of Origin
Henan, China
  • Reply within one working day
  • Factory-direct pricing, OEM & ODM accepted
  • Full specification and test reports supplied

Get Factory Pricing

Price, MOQ and lead time direct from the manufacturer. Free, no account needed.

Enquiring about Split Air Conditioners, 840, DC

Split air conditioners — capacity 840,000, power type DC. The complete factory specification follows. Made by Henan Youngye Sunshine New Energy Technology Co., Ltd. (3 years on the platform, typical reply ≤7h). Send your target quantity and destination for a firm quotation with current lead times.

Key Features of These Split Air Conditioners

  • Model Number: RUXYQ88BBN
  • Power Type: DC
  • Power Source: Electric
  • Power (W): 69.2kw
  • Horsepower: 88HP
  • Capacity (Btu): 840,000

Technical Specifications

Type Central Air Conditioners
Capacity (Btu) 840,000
Cooling/Heating Cooling/Heating
Application Outdoor, Office, Household, Commercial, Hotel
Energy Efficiency Rating Class A
EER 3.55
Fixed Frequency/Variable Frequency Variable Frequency
Power Type DC
Power Source Electric
Refrigerant R410A
App-Controlled Yes
Feature Energy-Saving, Remote Control, Air Purification Function, Wifi
Remote Control Yes
Power (W) 69.2kw
Warranty 1 Year
After-Sales Service Provided Free Spare Parts
Operating Language English
Private Mold No
Packaging Types Corrugated Box
Place Of Origin Henan, China
Recommended Room Size(Square Feet) ≥100
Brand Name DAIKIN
Cop 4.06
Maximum Airflow Rate 65040m³/h
Model Number RUXYQ88BBN
Product Name Daikin VRV X7 Multi-Split Central Air Conditioner
Horsepower 88HP
Rated Cooling Capacity 246KW
Rated Heating Capacity 276KW
Fan Air Volume 271+271+271+271m³/min
Noise 66-69db(A)
Weight 1200kg
Operating Range Cooling:-15~54°CDB Heating:-25~27°CDB
Unit Dimensions (HxWxD) 1657x1240x765+1657x1240x765+1657x1240x765+1657x1240x765mm
Selling Units Single item
Single Volume 0 cm³
Single Gross Weight 0.0 kg

Product Details

Split Air Conditioners, 840, DC - detail 1Split Air Conditioners, 840, DC - detail 2
VRV X7 Series
Split Air Conditioners, 840, DC - detail 3Split Air Conditioners, 840, DC - detail 4
Model
RUXYQ8BBN
RUXYQ10BBN
RUXYQ12BBN
RUXYQ14BBN
RUXYQ16BBN
RUXYQ18BBN
RUXYQ20BBN
RUXYQ22BBN
Horsepower 
HP
8
10
12
14
16
18
20
22
Power Supply
Three-phase 380V 50Hz
Rated Cooling Capacity 
KW
22.4
28
33.5
40
45
50.4
56.5
61.5
Rated Heating Capacity 
KW
25
31.5
37.5
45
50
56.5
63
69
Rated Power Consumption kW
Cooling
4.7
6.71
8.1
9.88
11.8
12.8
14.7
17.3
Heating
5.24
6.72
8.48
10.5
12.1
13.3
15.3
17
Fan Air Volume 
m³/min
162
175
185
223
280
271
271
271
Unit Dimensions 
(HxWxD) mm
1657x930x765
1657x1240x765
Operating Noise dB(A)
Front-side Operating Noise
53
54
56
56
57
58
59
60
Four-side Operating Noise
56
57
59
59
60
61
62
63
Night Silent Operation
 dB(A)
40
Indoor/Outdoor Unit Pipe Connection Diameter
Liquid Pipe (mm)
Ф9.5
Ф9.5
Ф12.7
Ф12.7
Ф12.7
Ф15.9
Ф15.9
Ф15.9
Gas Pipe(mm)
Ф19.1
Ф22.2
Ф25.4
Ф25.4
Ф28.6
Ф28.6
Ф28.6
Ф28.6
Outdoor Unit Pipe Connection Diameter
Liquid Pipe(mm)
Ф9.5
Ф9.5
Ф9.5
Ф12.7
Ф12.7
Ф12.7
Ф12.7
Ф12.7
Gas Pipe(mm)
Ф19.1
Ф25.4
Ф25.4
Ф25.4
Ф25.4
Ф28.6
Ф28.6
Ф28.6
Weight
kg
189
196
196
250
280
300
300
300
Refrigerant
Name
R410A
Filling volume kg
8.4
8.6
8.7
11.1
11.1
15.6
15,6
15.6
Operating Range
°CDB
Cooling
-15~54°CDB
Heating
-25~27°CDB
Minimum Circuit Current
MCA (A)
16.1
18
20.1
24.4
26
34.8
39.6
43.6
Maximum Fuse Current
MFA  (A)
20
20
25
32
32
40
50
50
Intelligent Control Module (Optional)
Model
BRG8AC5
BRG22AC5
Dimensions(HxWxD) mm

45x265x335
Model
RUXYQ24BBN
RUXYQ26BBN
RUXYQ28BBN
RUXYQ3OBBN
RUXYQ32BBN
RUXYQ34BBN
RUXYQ36BBN
RUXYQ38BBN
Horsepower 
HP
24
26
28
30
32
34
36
38
Combination method
RUXYQ10BBN
RUXYQ14BBN
RUXYQ12BBN
RUXYQ14BBN
RUXYQ8BBN
RUXYQ20BBN
RUXYQ8BBN
RUXYQ22BBN
RUXYQ10BBN
RUXYQ22BBN
RUXYQ12BBN
RUXYQ22BBN
RUXYQ14BBN
RUXYQ22BBN
RUXYQ18BBN
RUXYQ20BBN
Power Supply
Three-phase 380V 50Hz
Rated Cooling Capacity 
KW
68
73.5
78.9
83.9
89.5
95
101.5
106.9
Rated Heating Capacity 
KW
76.5
82.5
88
94
100.5
106.5
114
119.5
Rated Power Consumption kW
Cooling
16.6
18
19.4
22
24
25.4
27.2
27.5
Heating
17.2
19
20.5
22.2
23.7
25.5
27.5
28.6
Fan Air Volume 
m³/min
175+
223
185+
223
162+
271
162+
271
175+
271
185+
271
223+
271
271+
271
Unit Dimensions 
(HxWxD) mm
1657x930x765+1657x1240x765
1657x1240x765+1657x1240x76
Operating Noise dB(A)
Front-side Operating Noise
58
59
60
61
61
62
62
62
Four-side Operating Noise
61
62
63
64
64
65
65
65
Night Silent Operation
 dB(A)
43
Indoor/Outdoor Unit Pipe Connection Diameter
Liquid Pipe (mm)
Ф15.9
Ф19.1
Ф19.1
Ф19.1
Ф19.1
Ф19.1
Ф19.1
Ф19.1
Gas Pipe(mm)
Ф28.6
Ф31.8
Ф31.8
Ф31.8
Ф31.8
Ф31.8
Ф31.8
Ф31.8
Weight
kg
446
446
489
489
496
496
550
600
Refrigerant
Name
R410A
Filling volume kg
8.6+
11.1
8.7+
11.1
8.4+
15.6
8.4+
15.6
8.6+
15.6
8.7+
15.6
11.1+
15.6
15.6+
15.6
Operating Range
°CDB
Cooling
-15~54°CDB
Heating
-25~27°CDB
Minimum Circuit Current
MCA (A)
40.2
44
46.1
59.7
61.6
63.7
68
69.6
Maximum Fuse Current
MFA  (A)
50
50
63
80
80
80
80
80
Model
RUXYQ4OBBN
RUXYQ42BBN
RUXYQ44BBN
RUXYQ46BBN
RUXYQ48BBN
RUXYQ50BBN
RUXYQ52BBN
RUXYQ54BBN
Horsepower 
HP
40
42
44
46
48
50
52
54
Combination method
RUXYQ18BBNRUXYQ22BBN
RUXYQ2OBBNRUXYQ22BBN
RUXYQ22BBNRUXYQ22BBN
RUXYQ10BBNRUXYQ14BBNRUXYQ22BBN
RUXYQ12BBNRUXYQ14BBNRUXYQ22BBN
RUXYQ8BBNRUXYQ20BBNRUXYQ22BBN
RUXYQ10BBNRUXYQ20BBNRUXYQ22BBN
RUXYQ10BBNRUXYQ22BBNRUXYQ22BBN
Power Supply
Three-phase 380V 50Hz
Rated Cooling Capacity 
KW
111.9
118
123
129.5
135
140.4
146
151
Rated Heating Capacity 
KW
125.5
132
138
145.5
151.5
157
163.5
169.5
Rated Power Consumption kW
Cooling
30.1
32
34.6
33.9
35.3
36.7
38.7
41.3
Heating
30.3
32.3
34
34.2
36
37.5
39
40.7
Fan Air Volume 
m³/min
271+271
271+271
271+271
175+223+271
185+223+271
162+271+271
175+271+271
175+271+271
Unit Dimensions 
(HxWxD) mm
1657x1240x765+1657x1240x765
1657x930x765+1657x1240x765+1657x1240x765
Operating Noise dB(A)
Front-side Operating Noise
62
63
63
62
63
63
62
62
Four-side Operating Noise
65
66
66
65
66
66
65
65
Night Silent Operation
 dB(A)
43
45
Indoor/Outdoor Unit Pipe Connection Diameter
Liquid Pipe (mm)
Ф19.1
Ф19.1
Ф19.1
Ф19.1
Ф19.1
Ф19.1
Ф19.1
Ф19.1
Gas Pipe(mm)
Ф31.8
Ф31.8
Ф31.8
Ф31.8
Ф31.8
Ф31.8
Ф31.8
Ф31.8
Weight
kg
600
600
600
746
746
789
796
796
Refrigerant
Name
R410A
Filling volume kg
15.6+15.6
15.6+15.6
15.6+15.6
8.6+11.1+15.6
8.7+11.1+15.6
8.4+15.6+15.6
8.6+15.6+15.6
15.6+15.6
Operating Range
°CDB
Cooling
-15~54°CDB
Heating
-25~27°CDB
Minimum Circuit Current
MCA (A)
78.4
83.2
87.2
85.7
87.6
89.7
101.2
105.2
Maximum Fuse Current
MFA  (A)
100
100
100
100
100
100
125
125
Model
RUXYQ56BBN
RUXYQ58BBN
RUXYQ60BBN
RUXYQ62BBN
RUXYQ64BBN
RUXYQ66BBN
RUXYQ68BBN
RUXYQ70BBN
Horsepower 
HP
56
58
60
62
64
66
68
70
Combination method
RUXYQ12BBN
RUXYO22BBN
RUXYQ22BBN
RUXYQ14BBN
RUXYQ22BBN
RUXYQ22BBN
RUXYQ20BBN
RUXYQ20BBN
RUXYQ20BBN
RUXYQ18BBN
RUXYO22BBN
RUXYQ22BBN
RUXYQ20BBN
RUXYQ22BBN
RUXYQ22BBN
RUXYQ22BBN
RUXYQ22BBN
RUXYQ22BBN
RUXYQ12BBN
RUXYQ12BBN
RUXYQ22BBN
RUXYQ22BBN
RUXYO12BBN
RUXYQ14BBN
RUXYQ22BBN
RUXYQ22BBN
Power Supply
Three-phase 380V 50Hz
Rated Cooling Capacity 
KW
156.5
163
169.5
173.4
179.5
184.5
190
196.5
Rated Heating Capacity 
KW
175.5
183
189
94.5
201
207
213
220.5
Rated Power Consumption kW
Cooling
42.7
44.5
44.1
47.4
49.3
51.9
50.8
52.6
Heating
42.5
44.5
45.9
47.3
49.3
51
51
53
Fan Air Volume 
m³/min
185+271+271
223+271+271
271+271+271
271+271+271
271+271+271
271+271+271
185+185+271+271
185+223+271+271
Unit Dimensions 
(HxWxD) mm
1657x930x765+1657x1240x765+1657x1240x765
1657x1240x765 + 1657x1240x765 + 1657x1240x765
1657x930x765+1657x930x765+1657x1240x765+1657x1240x765
1657x930x765 + 1657x1240x765 + 1657x1240x765 + 1657x1240x765
Operating Noise dB(A)
Front-side Operating Noise
64
64
64
64
65
66
65
65
Four-side Operating Noise
67
67
67
67
68
69
68
68
Night Silent Operation
 dB(A)
45
46
46
Indoor/Outdoor Unit Pipe Connection Diameter
Liquid Pipe (mm)
Ф19.1
Ф19.1
Ф19.1
Ф19.1
Ф19.1
Ф19.1
Ф19.1
Ф19.1
Gas Pipe(mm)
Ф41.3
Ф41.3
Ф41.3
Ф41.3
Ф41.3
Ф41.3
Ф44.5
Ф44.5
Weight
kg
796
850
900
900
900
900
992
1046
Refrigerant
Name
R410A
Filling volume kg
8.7+15.6+15.6
11.1+15.6+15.6
15.6+15.6+15.6
8.7+8.7+15.6+15.6
8.7+11.1+15.6+15.6
Operating Range
°CDB
Cooling
-15~54°CDB
Heating
-25~27°CDB
Minimum Circuit Current
MCA (A)
107.3
111.6
113.2
122
126.8
130.8
127.4
131.7
Maximum Fuse Current
MFA  (A)
125
125
125
140
140
160
160
160
Indoor Unit Model
RUXYQ72BBN
RUXYQ74BBN
RUXYQ76BBN
RUXYQ78BBN
RUXYQ80BBN
RUXYQ82BBN
RUXYQ84BBN
RUXYQ86BBN
Horsepower
HP
72
74
76
78
80
82
84
86
Combination method
RUXYQ12BBNRUXYQ16BBNRUXYQ22BBNRUXYQ22BBN
RUXYQ12BBNRUXYQ18BBNRUXYQ22BBNRUXYQ22BBN
RUXYQ10BBNRUXYQ22BBNRUXYQ22BBNRUXYQ22BBN
RUXYO12BBNRUXYQ22BBNRUXYQ22BBNRUXYQ22BBN
RUXYQ14BBNRUXYQ22BBNRUXYQ22BBNRUXYQ22BBN
RUXYQ16BBNRUXYQ22BBNRUXYQ22BBNRUXYQ22BBN
RUXYQ18BBNRUXYQ22BBNRUXYO22BBNRUXYQ22BBN
RUXYQ20BBNRUXYO22BBNRUXYO22BBNRUXYQ22BBN
Power Supply
Three-phase 380V 50Hz
Rated Cooling Capacity
KW
201.5
206.9
212.5
218
224.5
229.5
234.9
241
Rated Heating Capacity
KW
225.5
232
238.5
244.5
252
257
263.5
270
Rated Power Consumption kW
Cooling
54.5
55.5
58.6
60
61.8
63.7
64.7
66.6
Heating
54.6
55.8
57.7
59.5
61.5
63.1
64.3
66.3
Fan Air Volume
m³/min
185+280+271+271
185+271+271+271
175+271+271+271
185+271+271+271
223+271+271+271
280+271+271+271
271+271+271+271
271+271+271+271
Unit Dimensions
(HxWxD) mm
1657x930x765 + 1657x1240x765 + 1657x1240x765 + 1657x1240x765
1657x1240x765 + 1657x1240x765 + 1657x1240x765 + 1657x1240x765
Operating Noise dB(A)
Front-side Operating Noise
65
66
66
65
66
66
66
66
Four-side Operating Noise
68
69
69
68
69
69
69
69
Night Silent Operation
dB(A)
46
Indoor/Outdoor Unit Pipe Connection Diameter
Liquid Pipe (mm)
Ф19.1
Ф19.1
Ф19.1
Ф19.1
Ф22.2
Ф22.2
Ф22.2
Ф22.2
Gas Pipe(mm)
Ф44.5
Ф44.5
Ф44.5
Ф44.5
Ф44.5
Ф44.5
Ф44.5
Ф44.5
Weight
kg
1076
1096
1096
1096
1150
1180
1200
1200
Refrigerant
Name
R410A
Filling volume kg
8.7+11.1+15.6+15.6
8.7+15.6+15.6+15.6
8.6+15.6+15.6+15.6
8.7+15.6+15.6+15.6
11.1+15.6+15.6+15.6
15.6+15.6+15.6+15.6
Operating Range°CDB
Cooling
-15~45°CDB
Heating
-25~27°CDB
Minimum Circuit Current
MCA (A)
133.3
142.1
148.8
150.9
155.2
156.8
165.6
170.4
Maximum Fuse Current
MFA (A)
160
160
200
200
200
200
200
200
Technological advantages

Super Technology Create more value

*High-performance VRV central air conditioning systems are more efficient than you think
The Daikin VRV central air conditioning system is designed not only to make the air conditioner work, but also to make it operate more efficiently, bringing you unimaginable value. Daikin's VOS7.0 control logic, the new V-Power technology high-pressure scroll compressor, the Gircle integrated four-sided heat exchanger, and the high-torque motor—these meticulously crafted features come together to create the ultra-high efficiency Daikin VRVX7 series, achieving energy savings of approximately 10%*.
*Energy efficiency has been further improved, resulting in higher operating costs and greater economic benefits
Traditional central air conditioning systems have numerous energy-consuming components, including the main unit, indoor units, cooling towers, boilers, and water system power consumption. With so many power-consuming devices, the actual operating efficiency of the system is not high. Daikin's VRVX7 series, employing VRV multi-split technology, consumes only the outdoor and indoor units, along with several upgraded accessories, resulting in a more efficient and energy-saving system.
*Large capacity and compact outdoor unit design overcomes the challenges of tight outdoor unit installation space
In modern buildings where every inch of space is precious, the space required for equipment installation is constantly being reduced in order to maximize rental and sales space and generate more rental and sales profits. The VRVX7 series is equipped with Daikin's latest New V-Power technology high-pressure scroll compressor, achieving a groundbreaking design of a large-capacity, compact outdoor unit. It strives to maximize the space utilization efficiency of modern buildings, saving up to 35%* of equipment floor space.
Split Air Conditioners, 840, DC - detail 5Split Air Conditioners, 840, DC - detail 6

Ultra-stable and unaffected by extreme weather

*45°C – No temperature decay during cooling
We face real ultra-high temperature operating conditions. When adopting the new VRV air conditioning system design, even at ultra-high temperatures of 45°C, the cooling capacity can be achieved without temperature decay.
*54°C Continuous cooling operation
Extreme heat and poor heat dissipation in outdoor units can lead to ineffective cooling. The heat island effect caused by placing multiple outdoor units together is often a heat dissipation problem that designers encounter when pursuing creative designs by centrally arranging air conditioners. However, solving these air conditioning problems is precisely what Daikin excels at.
*24% improvement in heating performance
The VRVX7 series features a combination of advanced technology, including rapid heating start-up and multi-dimensional intelligent defrosting, resulting in a comprehensive improvement in heating capacity, up to 24%, ensuring a comfortable heating experience for you.
Split Air Conditioners, 840, DC - detail 7Split Air Conditioners, 840, DC - detail 8

Ultra-energy-saving technology continues to contribute to green and low-carbon development

Daikin's VRV air conditioning system, combined with intelligent control modules and smart IoT, helps traditional buildings further transform into low-carbon structures, reduces air conditioning energy consumption, and contributes to the construction of low-carbon and green cities.
*Professional air conditioning maintenance saves approximately 3% on energy
*The worry-free energy-saving mode saves approximately 10% on energy
*Comfort and energy-saving mode saves approximately 15% on energy
*Adaptive energy-saving mode saves approximately 15% of energy
Split Air Conditioners, 840, DC - detail 9Split Air Conditioners, 840, DC - detail 10

IPLV(C) Breakthrough

A breakthrough in IPLV(C): IPLV(C) values ​​can reach up to 10.0, with an average IPLV(C) value exceeding 9.43.
Split Air Conditioners, 840, DC - detail 11Split Air Conditioners, 840, DC - detail 12

FLYHIGH refrigerant loop design comprehensively improves system performance

The VRV X7 series utilizes the FLYHGH refrigerant circuit design, optimizing and upgrading the refrigerant subcooling circuit structure inside the outdoor unit. This enables more precise control of the system refrigerant, further breaking through the system pipe length limit and enhancing the air conditioning capacity when the system employs a long piping design. This makes outdoor unit placement more convenient in high-rise and super high-rise buildings, while also providing superior air conditioning performance.
Split Air Conditioners, 840, DC - detail 13Split Air Conditioners, 840, DC - detail 14
FLYHIGH refrigerant loop design
*The main pipe is 1000m long
*Maximum height difference between indoor and outdoor units:
100m outdoor unit above indoor unit 110m outdoor unit below indoor unit
*Maximum actual single pipe length 240m
*Maximum equivalent single tube length 280m
*The maximum pipe length after the first branch pipe is 120m.
No need for air conditioning unit louvers; building facade design is no longer limited by outdoor unit placement requirements.
Each floor does not require an outdoor equipment room, aiming to minimize public space and create more high-quality rental area.

VOS 7.0 control logic fully upgraded

The Daikin VRVX7 series air conditioning system features Daikin's latest VOS7.0 control logic. Unlike the control logic of common multi-split systems (indoor and outdoor unit linkage control logic), it achieves a groundbreaking new control logic: linkage control logic between indoor and outdoor units and multiple indoor units. It monitors the dynamic changes in indoor air conditioning load in real time and adaptively adjusts refrigerant flow, refrigerant temperature, and the air circulation volume of each indoor unit and outdoor unit. Coupled with optimized crankshaft heating control technology, this further improves the energy efficiency of the air conditioning system while significantly enhancing user comfort and preventing excessive indoor temperature fluctuations.
Split Air Conditioners, 840, DC - detail 15Split Air Conditioners, 840, DC - detail 16

IoT Intelligent Control System

One intelligent control module can connect to up to 7 systems/64 indoor units, facilitating intelligent management and control of the air conditioning system.
*Remote web control via computer/mobile phone/tablet.
*User account hierarchical permission management.
*Centralized control / Area control / Individual control (on/off, temperature adjustment, mode switching, fan speed adjustment, airflow direction adjustment).
*Schedule. *Air conditioner indoor unit linkage settings.
*Monitoring function, displays the air conditioner's operating status.
*Fault display function; Multi-project management
*Open API Port *Energy Consumption Visualization *Easy Energy Saving Mode (Schedule Setting) *Comfort Energy Saving Mode (Permission Settings) *Adaptive Energy Saving Mode (Peak Shaving)
*Energy-saving health check report,Energy-saving diagnosis *Air quality visualization, linked with Daikin fresh air system
Split Air Conditioners, 840, DC - detail 17Split Air Conditioners, 840, DC - detail 18

Energy consumption visualization

Schematic diagram of energy consumption visualization/air quality visualization/fresh air linkage system.
Split Air Conditioners, 840, DC - detail 19Split Air Conditioners, 840, DC - detail 20
Split Air Conditioners, 840, DC - detail 21Split Air Conditioners, 840, DC - detail 22

Wider operating range

Heating continuous operation range down to -25°C
Split Air Conditioners, 840, DC - detail 23Split Air Conditioners, 840, DC - detail 24

Short heating start-up time

The compressor starts at full speed to provide rapid heating

Six special defrosting mechanisms

*Partial Load Defrosting Mechanism When the system is operating at full load, the defrosting timing is accurately determined based on changes in the outdoor unit's heat exchange temperature difference. Under partial load, the defrosting timing is accurately determined based on changes in the outdoor unit's heat exchange efficiency.
*High Humidity Environment Defrosting Mechanism
The higher the ambient humidity, the easier it is for the unit to frost. Daikin units can judge the ambient humidity by the data from each defrosting operation, so as to perform defrosting operation more accurately and avoid ineffective defrosting or excessive frost.
*Dust Accumulation Learning Defrosting Mechanism
By comparing data before and after each defrost, Daikin units can accurately determine changes in heat exchange efficiency caused by dust accumulation, thereby reducing ineffective defrosting caused by heat exchanger contamination.
*Low-Temperature Defrosting Mechanism
When defrosting is difficult, extending the heating time can reduce heat loss during defrosting. When the outdoor temperature is even lower, the unit automatically corrects the temperature sensor data based on the outside air temperature, making the data more accurate and ensuring more precise defrosting timing.
*Modular alternating defrosting mechanism
When two or more outdoor units are combined into a system, the system can use the heat from the outside air to alternately defrost, which can alleviate the drop in room temperature, shorten the recovery time after defrosting, and thus improve comfort.
*Coil heat storage defrosting mechanism
Before entering defrosting mode, the refrigerant temperature is increased to achieve heat storage effect of the indoor unit heat exchanger. After the defrosting mode ends, the heat stored in the coil is automatically used to heat the room, so that the indoor temperature can be restored as soon as possible.
Split Air Conditioners, 840, DC - detail 25Split Air Conditioners, 840, DC - detail 26

Multiple advanced functions for greater stability

The Daikin VRVX7 series features a user-friendly and efficient commissioning function that automatically detects whether the wiring, piping, refrigerant filling, and shut-off valve settings are correct. This not only significantly improves construction speed but also effectively enhances the quality of on-site construction.
Split Air Conditioners, 840, DC - detail 27Split Air Conditioners, 840, DC - detail 28
Applicable Scenarios
Split Air Conditioners, 840, DC - detail 29Split Air Conditioners, 840, DC - detail 30
Company Introduction
Split Air Conditioners, 840, DC - detail 31Split Air Conditioners, 840, DC - detail 32
Yangyesunshine New Energy – a high-tech enterprise focusing on thermal energy and air conditioning. With 16 years of experience in clean thermal energy, we specialize in solar energy, air source heat pumps, and central air conditioning technologies, providing a full-chain service from R&D and design to installation and after-sales support. We have completed over 1000 benchmark projects nationwide, empowering our clients with one-stop solutions. Upholding the spirit of "Integrity, Professionalism, Pragmatism, and Progress," we offer 24/7 online service and attentive quality. We practice environmental protection and energy conservation, pursuing harmonious coexistence between humanity and nature.
*Our official website: yangyesunshine.com
Split Air Conditioners, 840, DC - detail 33Split Air Conditioners, 840, DC - detail 34
Packing&Shipping
Split Air Conditioners, 840, DC - detail 35Split Air Conditioners, 840, DC - detail 36
Split Air Conditioners, 840, DC - detail 37Split Air Conditioners, 840, DC - detail 38
Split Air Conditioners, 840, DC - detail 39Split Air Conditioners, 840, DC - detail 40
Split Air Conditioners, 840, DC - detail 41Split Air Conditioners, 840, DC - detail 42
Split Air Conditioners, 840, DC - detail 43Split Air Conditioners, 840, DC - detail 44

FAQ:

Q1: How is the product quality control being handled?
A: "Quality is our top priority." Our team takes quality control very seriously from start to finish.

Q2: Where is your packaging?
A: Standard packaging:
FCL (Full Container Load): Inner bags with outer export carton packaging
LCL (Less than Container Load): Plywood box + carton packaging

Q3: What about your air conditioners?
A: All our air conditioners are designed according to market requirements.

Q4: How can I obtain after-sales service?
A: If the issue is caused by us, we will send you spare parts for free.
If it's a human-induced issue, we will also send spare parts, but you will need to pay for them.
For our air conditioners, we offer lifetime maintenance.

Q5: Do you have an inspection procedure for air conditioners?
A: We conduct a 100% self-inspection before packaging.

Ordering and Pricing

  • Minimum order quantity: 1 set
  • Ships from: China
  • Customization: OEM and ODM accepted on qualifying volumes.

Frequently Asked Questions

What is the minimum order quantity for this split air conditioners?

The standard minimum order quantity is 1 set. Trial orders can usually be arranged for buyers evaluating the product before a full production run.

What warranty is provided?

The manufacturer provides a 1 Year warranty. Spare parts and technical support remain available after the warranty period.

Do you accept OEM or custom branding?

Yes. Custom logo, colour, packaging and specification changes are accepted on qualifying order volumes. Send your artwork and technical requirements with your enquiry.

How long does production and delivery take?

In-stock configurations typically ship within 7–15 days. Customised or large-volume orders are usually produced in 25–35 days, confirmed on order.

About the Manufacturer

This product is produced by Henan Youngye Sunshine New Energy Technology Co., Ltd., based in China. The company 3 years as a verified Alibaba.com supplier, Trading Company. Browse the full Henan Youngye Sunshine New Energy Technology Co., Ltd. range on HVACR Nexus.

Type

Central Air Conditioners

Capacity (Btu)

840,000

Cooling/Heating

Cooling/Heating

Application

Outdoor, Office, Household, Commercial, Hotel

Energy Efficiency Rating

Class A

EER

3.55

Fixed Frequency/Variable Frequency

Variable Frequency

Power Type

DC

Power Source

Electric

Refrigerant

R410A

App-Controlled

Yes

Feature

Energy-Saving, Remote Control, Air Purification Function, Wifi

Remote Control

Yes

Power (W)

69.2kw

Warranty

1 Year

After-Sales Service Provided

Free Spare Parts

Operating Language

English

Private Mold

No

Packaging Types

Corrugated Box

Place Of Origin

Henan, China

Brand Name

DAIKIN

Cop

4.06

Maximum Airflow Rate

65040m³/h

Model Number

RUXYQ88BBN

Product Name

Daikin VRV X7 Multi-Split Central Air Conditioner

Horsepower

88HP

Rated Cooling Capacity

246KW

Rated Heating Capacity

276KW

Fan Air Volume

271+271+271+271m³/min

More from Henan Youngye Sunshine New Energy Technology Co., Ltd.

Other equipment from the same manufacturer — one enquiry can cover several items.

Compare Other Split Air Conditioners

Alternatives in the same category, from different verified suppliers.

Explore related

Specifications, certifications and images on this page are as published by the manufacturer and have not been independently tested or verified by HVACR Nexus. Confirm the full specification and the approvals valid in your market in writing before ordering. Content & IP notice