Cooling Tower, 0, Metal - view 2
Cooling Tower, 0, Metal - view 3
Cooling Tower, 0, Metal - view 4
Cooling Tower, 0, Metal - view 5
Cooling Tower, 0, Metal - view 6

Cooling Tower, 0, Metal

$9,700.00

Cooling Tower — voltage 0, material Metal. Factory-direct from a verified manufacturer, full specification published. Type: Flow Cooling Tower.

Voltage
0
Power(W)
0
Material
Metal
Warranty
1 Year
Place Of Origin
Tianjin, China
Type
Flow Cooling Tower
  • Reply within one working day
  • Factory-direct pricing, OEM & ODM accepted
  • Full specification and test reports supplied

Get Factory Pricing

Free quotation direct from the manufacturer — price, MOQ and lead time, usually within one working day. No account needed.

Enquiring about Cooling Tower, 0, Metal

This cooling tower is published with the manufacturer’s full specification — voltage 0, material Metal. Made by Tianjin Latino Environmental Technology Co., Ltd. (10 years on the platform, factory-assessed). For a binding price and lead time, send the volume you need and where it ships to.

Key Features of This Cooling Tower

  • Power(W): 0
  • Voltage: 0
  • Material: Metal
  • Coil Material: Ss304/galvnised Steel
  • Warranty: 1 Year
  • Place Of Origin: Tianjin, China

Technical Specifications

Voltage 0
Cooling Type Counter Flow
Power(W) 0
Material Metal
Core Components PLC
Machinery Test Report Provided
Warranty 1 Year
Video Outgoing-Inspection Provided
Key Selling Points Eco-Friendly
Place Of Origin Tianjin, China
Weight (Kg) 1500
Brand Name Latino
Product Name Counter Flow Closed Cooling Tower
Application Industrial Fluids Cooling
Name Water Cooling System Cooling Tower
Type Flow Cooling Tower
Shape Square Shape
Keyword Industrial Evaporative Condenser
Usage Cooing Tower
Other Name Cooling Machine
Color Stainless Steel
Coil Material Ss304/galvnised Steel
Selling Units Single item
Single Package Size 500X200X200 cm
Single Gross Weight 1000.0 kg

Product Details

Fluid Cooler Cooling Tower Evaporative Fluid Series Closed Circuit Cooling Towers

Closed circuit cooling towers, also known as evaporative fluid coolers, keep the system clean and contaminant-free in a closed loop. This creates two separate fluid circuits: (1) an external circuit, in which spray water circulates over the coil and mixes with the outside air, and an internal circuit, in which the process fluid to be cooled circulates inside the coil.  During operation, heat is transferred from the warm fluid in the coil to the spray water, and then to the atmosphere as a portion of the water evaporates. In addition to chiller applications and industrial process cooling, closed circuit cooling towers are often used with heat pump systems, where closed loop cooling is required.

 

Principle of Operation

Closed circuit cooling towers operate in a manner similar to open cooling towers, except that the heat load to be rejected is transferred from the process fluid (the fluid being cooled) to the ambient air through a heat exchange coil. The coil serves to isolate the process fluid from the outside air, keeping it clean and contaminant-free in a closed loop. This creates two separate fluid circuits: (1) an external circuit, in which spray water circulates over the coil and mixes with the outside air, and an internal circuit, in which the process fluid circulates inside the coil. During operation, heat is transferred from the internal circuit, through the coil to the spray water, and then to the atmosphere as a portion of the water evaporates.

Cooling Tower, 0, Metal - detail 1Cooling Tower, 0, Metal - detail 2

 

Advantages of Closed Circuit Cooling Towers

Open cooling towers expose process cooling water to the atmosphere, typically as part of a chiller system loop.  Open towers use an efficient, simple, and economical design.  All components in an open system must be compatible with the oxygen introduced via the cooling tower.

 

Closed circuit cooling towers completely isolate the process cooling fluid from the atmosphere.  This is accomplished by combining the heat rejection equipment with a heat exchanger in a closed circuit tower.  A closed loop system protects the quality of the process fluid, reduces system maintenance, and provides operational flexibility at a slightly higher initial cost.

 

 

Model

(Tons)

weight

(kg)

Dimensions

(mm)

Main

Circulator

Voltage

(V)

Flow of main

motor 

(m³/h) 

 

Diameter of

inlet and outlet

(mm)

 

Heat transfer

capacity

(kal/h)

Fan

Power

(KW)

Fan volume

(m³/h)

Working

Power

(KW)

 

Working

Pressure

(MPa)

40 1150 2750*1200*2100 5.5*2 380 46.7 DN65 301750 1.1*2 17000*2 7.5 0.15-0.25
60 1250 2750*1380*2230 5.5*2 380 46.7 DN80 301750 1.1*2 17000*2 7.5 0.15-0.25
70 1450 2750*1500*2230 5.5*3 380 46.7 DN80 401300 1.1*2 17000*2 20 0.15-0.25
80 1450 2750*1500*2230 5.5*3 380 46.7 DN80 401300 1.5*2 19000*2 20 0.15-0.25
100 1790 2750*1860*2630 7.5*3 380 50 DN80 501800 1.1*4 17000*4 23.4 0.2-0.3
120 1945 2750*1980*2630 7.5*2 380 50 DN80 625300 1.1*4 17000*4 27 0.2-0.3
140 2450 3300*1930*2950 7.5*2 380 50 DN80 754200 1.1*6 17000*4 33 0.25-0.35
150 2650 3300*1980*2950 22*2 380 160 DN150 754200 1.1*6 17000*6 35 0.25-0.35
200 2900 3300*2050*2950 7.5*2 380 160 DN150 1062100 1.1*6 17000*6 40 0.25-0.35
320 2900 5350*2160*4250 22*3 380 320 DN150 1062100 1.1*12 17000*12 50 0.3-0.5

 

Product Details

Cooling Tower, 0, Metal - detail 3Cooling Tower, 0, Metal - detail 4

 

Anti-corrosion bolts and nuts

Cooling Tower, 0, Metal - detail 5Cooling Tower, 0, Metal - detail 6

 

 

Pipe with protruding

Cooling Tower, 0, Metal - detail 7Cooling Tower, 0, Metal - detail 8

 

 

Perfect sealing

Cooling Tower, 0, Metal - detail 9Cooling Tower, 0, Metal - detail 10

 

 

Core part:Coil pipe

Cooling Tower, 0, Metal - detail 11Cooling Tower, 0, Metal - detail 12

 

 

Pipe with spray nozzle

Successful Cases

Cooling Tower, 0, Metal - detail 13Cooling Tower, 0, Metal - detail 14

Cooling Tower, 0, Metal - detail 15Cooling Tower, 0, Metal - detail 16

Cooling Tower, 0, Metal - detail 17Cooling Tower, 0, Metal - detail 18

Cooling Tower, 0, Metal - detail 19Cooling Tower, 0, Metal - detail 20Cooling Tower, 0, Metal - detail 21Cooling Tower, 0, Metal - detail 22Cooling Tower, 0, Metal - detail 23Cooling Tower, 0, Metal - detail 24Cooling Tower, 0, Metal - detail 25Cooling Tower, 0, Metal - detail 26Cooling Tower, 0, Metal - detail 27Cooling Tower, 0, Metal - detail 28

Cooling Tower, 0, Metal - detail 29Cooling Tower, 0, Metal - detail 30

Q1: What about the lead time of cooling tower from placing a order to delivery?

A1: Standard production time is about 30days once confirmed PO. If you have any time limitation for cooling tower project, please kindly let us know when place order, we can put your order into urgently production.

 

Q2: Can you provide Mill Test Certificate?

A2: Yes no problem. The Mill Test Certificate , also known as Material Test Report, is a document that verifies a cooling tower’s chemical and physical properties. This can prove the cooling tower quality very well.

 

Q3: What kind of information request for quotation?

A3: Water flow rate, inlet and outlet temperature, dry bulb and wet bulb temperature, size limitation for water basin.

 

Q4:If the cooling tower can been customized for owned brand or color?

A4: Yes, available.

 

Q5:Can you provide OEM service for the cooling tower?

A5: Yes, we can provide OEM service for all the spare parts in the cooling tower.

 

Q6. How can we inspect the cooling tower parts before shipment?

A: Inspection by video or third party is available from us.

 

Ordering and Pricing

  • Minimum order quantity: 1 piece
  • Volume pricing:
    • 1–4 piece: US $9800 / piece
    • 5–9 piece: US $9750 / piece
    • 10+ piece: US $9700 / piece
  • Ships from: China
  • Customization: OEM and ODM accepted on qualifying volumes.

Frequently Asked Questions

What is the minimum order quantity for this cooling tower?

The standard minimum order quantity is 1 piece. Trial orders can usually be arranged for buyers evaluating the product before a full production run.

What warranty is provided?

The manufacturer provides a 1 Year warranty. Spare parts and technical support remain available after the warranty period.

Can the cooling tower be supplied for my local voltage?

The standard configuration is 0. Alternative voltage and frequency builds are available when specified at the time of order.

Do you accept OEM or custom branding?

Yes. Custom logo, colour, packaging and specification changes are accepted on qualifying order volumes. Send your artwork and technical requirements with your enquiry.

How long does production and delivery take?

In-stock configurations typically ship within 7–15 days. Customised or large-volume orders are usually produced in 25–35 days, confirmed on order.

About the Manufacturer

This product is produced by Tianjin Latino Environmental Technology Co., Ltd., based in China. The company 10 years as a verified Alibaba.com supplier, Trading Company, passed third-party supplier assessment. Browse the full Tianjin Latino Environmental Technology Co., Ltd. range on HVACR Nexus.

Voltage

0

Cooling Type

Counter Flow

Power(W)

0

Material

Metal

Core Components

PLC

Machinery Test Report

Provided

Warranty

1 Year

Video Outgoing-Inspection

Provided

Key Selling Points

Eco-Friendly

Place Of Origin

Tianjin, China

Weight (Kg)

1500

Brand Name

Latino

Product Name

Counter Flow Closed Cooling Tower

Application

Industrial Fluids Cooling

Name

Water Cooling System Cooling Tower

Type

Flow Cooling Tower

Shape

Square Shape

Keyword

Industrial Evaporative Condenser

Usage

Cooing Tower

Other Name

Cooling Machine

Color

Stainless Steel

Coil Material

Ss304/galvnised Steel

Selling Units

Single item

Single Package Size

500X200X200 cm

Single Gross Weight

1000.0 kg

More from Tianjin Latino Environmental Technology Co., Ltd.

Other equipment from the same manufacturer — one enquiry can cover several items.

Compare Other Dry Cooler

Alternatives in the same category, from different verified suppliers.

Explore related

Specifications, certifications and images on this page are as published by the manufacturer and have not been independently tested or verified by HVACR Nexus. Confirm the full specification and the approvals valid in your market in writing before ordering. Content & IP notice