Boiler: power supply 12~24VDC, material Plastic. Supplied direct from the factory with the complete specification. Type: Liquid Level Sensor.

Type
Liquid Level Sensor
Place Of Origin
Guangdong, China
Power Supply
12~24VDC
Power Supply
12~24VDC
Material
Plastic
  • Reply within one working day
  • Factory-direct pricing, OEM & ODM accepted
  • Full specification and test reports supplied

Get Factory Pricing

Price, MOQ and lead time direct from the manufacturer. Free, no account needed.

Enquiring about Boiler, 4-20mA, 12~24VDC, Plastic

Key specification for this boiler: power supply 12~24VDC, material Plastic. Everything below is reproduced from the factory data sheet. Made by Shenzhen Perfect Precision Products Co., Ltd. (8 years on the platform, factory-assessed). Send your target quantity and destination for a firm quotation with current lead times.

Key Features of This Boiler

  • Power Supply: 12~24VDC
  • Material: Plastic
  • Place Of Origin: Guangdong, China
  • Application: Water Treatment
  • Type: Liquid Level Sensor
  • Mounting Type: tank level sensor liquid

Technical Specifications

Theory ultrasonic pulse
Output RS485, 4-20mA
Type Liquid Level Sensor
Usage Liquid level inspection
Mounting Type tank level sensor liquid
Manufacturer Part Number SFU60R
Brand Name PFT
Description Level Sensor
Place Of Origin Guangdong, China
Application Water Treatment
Power Supply 12~24VDC
MOQ 1 Piece
Material Plastic
Selling Units Single item
Single Package Size 20X10X10 cm
Single Gross Weight 1.0 kg

Product Details

Boiler, 4-20mA, 12~24VDC, Plastic - detail 1Boiler, 4-20mA, 12~24VDC, Plastic - detail 2
Boiler, 4-20mA, 12~24VDC, Plastic - detail 3Boiler, 4-20mA, 12~24VDC, Plastic - detail 4
Boiler, 4-20mA, 12~24VDC, Plastic - detail 5Boiler, 4-20mA, 12~24VDC, Plastic - detail 6
Boiler, 4-20mA, 12~24VDC, Plastic - detail 7Boiler, 4-20mA, 12~24VDC, Plastic - detail 8
Boiler, 4-20mA, 12~24VDC, Plastic - detail 9Boiler, 4-20mA, 12~24VDC, Plastic - detail 10
Boiler, 4-20mA, 12~24VDC, Plastic - detail 11Boiler, 4-20mA, 12~24VDC, Plastic - detail 12
Boiler, 4-20mA, 12~24VDC, Plastic - detail 13Boiler, 4-20mA, 12~24VDC, Plastic - detail 14
Midel Category
SFU60A
SFU30B
SFU30M
SFU60R
Measuring Range
5m、8m、10m、12m、15m、20m、25m、30m
1m、2m

5m、8m、10m、12m、15m、20m、25m、30m
Measurement Blind Area
≤0.25~1.5m 
(change with the range)
≤0.06~0.15m 
(change with the range)

≤0.3~1.5m
 (change with the range)
Launching Angle (Full Angle)
Less than 10°
Less than 6°

Less than 12°
Accuracy
±0.3%F.S
±0.1%(±1mm or ±1.5mm)

±0.3%F.S
Resolution
1mm
1mm

1mm
Power Supply
DC12-24V or AC220V
Power consumption:<1.5W
DC12-24V
Power consumption:<1.5W

DC12-24V or AC220V
Power consumption:<5W
Output Singal
Current: 4~20mA, 0~20mA
Voltage: 0~5V, 0~10V
Numbers: RS485 (Modbus), GPRS wireless communication
Switch output: Two-way NPN, Two-way relay (AC: 5A/250V, DC: 10A/24V)
Current: 4~20mA, 0~20mA
Voltage: 0~5V, 0~10V
Numbers: RS485 (Modbus)
Switch output: Trhree-way NPN

Current: 4~20mA, 0~20mA
Voltage: 0~5V, 0~10V
Numbers: RS485 (Modbus), HART, GPRS MiniSD Data acquisition, USB
Switch output: 4-Channel relay output (AC: 5A/250V, DC: 10A/24V)
Connection Mode
5~10m: M60*2
20~30m: DN80 Non-standard flange
M30*1.5

5~10m: M60*2
20~30m: DN80 Non-standard flange
Leve Of Protection
Whole machine: IP65 or IP66/67, SensorIP68
Whole machine: IP65 or IP66/67, SensorIP68

Complete machine: IP65 or IP66/67, SensorIP68
Explosion-proof Leve
Exia IIB T4 Gb
Exia IIB T4 Gb

Exia IIB T4 Gb
 Exd IIB T4
Operating Environment
Normal temperature and pressure
Normal temperature and pressure

Normal temperature and pressure
Temperature Compensation
Full range automatic
Full range automatic

Full range automatic
Storage Humidity
≤80%RH, Free of dew
≤80%RH, Free of dew

≤80%RH, Free of dew
Application
Boiler, 4-20mA, 12~24VDC, Plastic - detail 15Boiler, 4-20mA, 12~24VDC, Plastic - detail 16
Beverage testing
Boiler, 4-20mA, 12~24VDC, Plastic - detail 17Boiler, 4-20mA, 12~24VDC, Plastic - detail 18
Sewage detection
Boiler, 4-20mA, 12~24VDC, Plastic - detail 19Boiler, 4-20mA, 12~24VDC, Plastic - detail 20
Marine lake detection
Boiler, 4-20mA, 12~24VDC, Plastic - detail 21Boiler, 4-20mA, 12~24VDC, Plastic - detail 22
Water accumulation detection
Boiler, 4-20mA, 12~24VDC, Plastic - detail 23Boiler, 4-20mA, 12~24VDC, Plastic - detail 24
Our Advantages
Boiler, 4-20mA, 12~24VDC, Plastic - detail 25Boiler, 4-20mA, 12~24VDC, Plastic - detail 26
Certifications
Boiler, 4-20mA, 12~24VDC, Plastic - detail 27Boiler, 4-20mA, 12~24VDC, Plastic - detail 28
Probe installation
Boiler, 4-20mA, 12~24VDC, Plastic - detail 29Boiler, 4-20mA, 12~24VDC, Plastic - detail 30

The probe generates ultrasonic pulse wave and detection echo at the same time, and the ultrasonic pulse wave propagates from the surface of the probe in a certain conical wave surface. In this area, there should be no obstruction and away from the feed port. The installation position of the probe should be selected in a position where there is no obstacle between the transmitting surface of the probe and the measured medium.
Boiler, 4-20mA, 12~24VDC, Plastic - detail 31Boiler, 4-20mA, 12~24VDC, Plastic - detail 32


The shape of the container should be considered when installing the probe. If the probe is not installed correctly, a container of a certain shape will produce a secondary echo. This kind of problem mainly focuses on the conical and spherical tank tops. This special shape allows the emitted echoes to be refocused and amplified to produce false readings. Choosing the right installation location can solve this problem.
Boiler, 4-20mA, 12~24VDC, Plastic - detail 33Boiler, 4-20mA, 12~24VDC, Plastic - detail 34

The probe can be installed with a flange or a standard G1-1/2 thread (the installation interface is subject to the actual object).Whether flange mounted or threaded, or with or without an optional cone, ensure that the bottom of the probe protrude from the bottom of the process interface.
Boiler, 4-20mA, 12~24VDC, Plastic - detail 35Boiler, 4-20mA, 12~24VDC, Plastic - detail 36

The probe shall be installed to avoid its emitted sound wave channel remaining within the ideal area shown on the diagram with the container wall. The range shown on the diagram is the area from which the probe is installed to the container wall. If the installation distance is less than the distance specified by the line of the ideal area, the probe should be installed within the "minimum spacing" area. If the mounting distance from the side wall is still below the "minimum spacing" line, the transmitter may not measure the level correctly.
Boiler, 4-20mA, 12~24VDC, Plastic - detail 37Boiler, 4-20mA, 12~24VDC, Plastic - detail 38

In solid material measurement, the probe should be typically installed at a distance of 1/3 of the side wall from the container wall to the center inlet. A cone will form as the material accumulates. The probe installation position will give a reading of the average level, which is the level height when the material is stacked flat. This is true for tapered deposits or concave deposits that appear during discharge. The average level height measured by this installation is correct only for cylindrical containers where the feed port is at the center line of the container. For containers of other shapes or where the feed port is not in the middle position, the probe shall be installed in accordance with the user's requirements and shall comply with the foregoing requirements.
Boiler, 4-20mA, 12~24VDC, Plastic - detail 39Boiler, 4-20mA, 12~24VDC, Plastic - detail 40


For liquids with a calm, waveless surface, ultrasonic measurements will yield the best results. If there is debris, bubbles or large fluctuations on the liquid surface, a waveguide should be installed. The waveguide should be larger than 120MM in diameter and have no connector.
FAQ
1. Q: What payment method your company accepts?
A: We accept T/T (Bank Transfer), Western Union, Paypal, Alipay, Wechat pay, L/C accordingly.

2. Q: How long for the production time?
A: For the in stock products, we usually take about 7~10 days, it still depends on order quantity.

3. Q: You said we can use our own logo?
A: Yes, we support customized logo.

4. Q: How long for delivery?
A: Usually take 3-7 days on delivery via express shipping methods.

5. Q: How do you control the quality?
A: (1)Material inspection–Check the material surface and roughly dimension.
(2)Production first inspection–To ensure the critical dimension in mass production.
(3)Sampling inspection–Check the quality before sending to the warehouse.
(4)Pre-shipment inspection–100% inspected by QC assistants before shipment.

6. Q: What will you do if we receive poor quality parts?
A: Please kindly send us the pictures, our engineers will find the solutions and remake them for you asap.

7. Q: How can I make a order?
A: You can send a inquiry to us, and you can tell our what's your requirement, then we can quote for you ASAP.

Ordering and Pricing

  • Minimum order quantity: 1 piece
  • Volume pricing:
    • 1–99 piece: US $200 / piece
    • 100+ piece: US $80 / piece
  • Ships from: China
  • Customization: OEM and ODM accepted on qualifying volumes.

Frequently Asked Questions

What is the minimum order quantity for this boiler?

The standard minimum order quantity is 1 piece. Trial orders can usually be arranged for buyers evaluating the product before a full production run.

Can the boiler be supplied for my local voltage?

The standard configuration is 12~24VDC. Alternative voltage and frequency builds are available when specified at the time of order.

Do you accept OEM or custom branding?

Yes. Custom logo, colour, packaging and specification changes are accepted on qualifying order volumes. Send your artwork and technical requirements with your enquiry.

How long does production and delivery take?

In-stock configurations typically ship within 7–15 days. Customised or large-volume orders are usually produced in 25–35 days, confirmed on order.

About the Manufacturer

This product is produced by Shenzhen Perfect Precision Products Co., Ltd., based in China. The company 8 years as a verified Alibaba.com supplier, operates its own manufacturing, passed third-party supplier assessment. Browse the full Shenzhen Perfect Precision Products Co., Ltd. range on HVACR Nexus.

Theory

ultrasonic pulse

Output

RS485, 4-20mA

Type

Liquid Level Sensor

Usage

Liquid level inspection

Mounting Type

tank level sensor liquid

Manufacturer Part Number

SFU60R

Brand Name

PFT

Description

Level Sensor

Place Of Origin

Guangdong, China

Application

Water Treatment

Power Supply

12~24VDC

MOQ

1 Piece

Material

Plastic

Selling Units

Single item

Single Package Size

20X10X10 cm

Single Gross Weight

1.0 kg

More from Shenzhen Perfect Precision Products Co., Ltd.

Other equipment from the same manufacturer — one enquiry can cover several items.

Compare Other Boiler Parts

Alternatives in the same category, from different verified suppliers.

Explore related

Specifications, certifications and images on this page are as published by the manufacturer and have not been independently tested or verified by HVACR Nexus. Confirm the full specification and the approvals valid in your market in writing before ordering. Content & IP notice