EC Model
|
Rated Voltage (V)
|
Operating Voltage (V)
|
Frequency (Hz)
|
Rated Current (A)
|
Rated Speed (RPM)
|
Rated Power (W)
|
Sound Level (dB)
|
Air Flow (CFM)
|
Air Pressure (Pa)
|
|
FD3G133-2AGL-70
|
230VAC
|
184–270
|
50/60
|
0.75
|
1500
|
105
|
64
|
752
|
205
|
|
FD3G146-2AGL-90
|
230VAC
|
184–270
|
50/60
|
1.4
|
1700
|
190
|
72.1
|
1200
|
425
|
|
FD3G146-2AGP-90
|
230VAC
|
184–270
|
50/60
|
2.2
|
1850
|
260
|
74
|
1499
|
540
|
|
FD3G146-2APV-90
|
230VAC
|
184–270
|
50/60
|
0.9
|
1650
|
150
|
69.6
|
1157
|
629
|
|
FD3G180-2AGL-20
|
230VAC
|
184–270
|
50/60
|
1.9
|
1550
|
400
|
74
|
2000
|
710
|
|
DC Model
|
Rated Voltage (V)
|
Operating Voltage (V)
|
Rated Current (A)
|
Rated Speed (RPM)
|
Rated Power (W)
|
Sound Level (dB)
|
Air Flow (CFM)
|
Air Pressure (Pa)
|
|
FD3G097-24GL-50
|
24
|
16~28
|
0.3
|
1400
|
7.2
|
43
|
150
|
250
|
|
FD3G097-48GL-50
|
48
|
36~57
|
0.15
|
1400
|
7.2
|
43
|
150
|
250
|
|
FD3G133-24GL-91
|
24
|
16~28
|
6
|
1780
|
144
|
68
|
760
|
500
|
|
FD3G133-48GL-91
|
48
|
36~57
|
3
|
1780
|
144
|
68
|
760
|
500
|
|
FD3G146-24GL-90
|
24
|
16~28
|
8.0
|
1700
|
190
|
66
|
1200
|
425
|
|
FD3G146-48GL-90
|
48
|
36~57
|
4.0
|
1700
|
190
|
66
|
1200
|
425
|
|
FD3G146-24GL-91
|
24
|
16~28
|
6.0
|
1580
|
144
|
61
|
960
|
250
|
|
FD3G146-48GL-91
|
48
|
36~57
|
3.0
|
1580
|
144
|
61
|
960
|
250
|
|
FD3G146-48PV-90
|
48
|
36~57
|
4.7
|
2050
|
223
|
63
|
1108
|
294
|
|
FD3G146-310PV-90
|
310
|
248~372
|
0.7
|
2050
|
223
|
63
|
1108
|
294
|
consumption, ensuring optimal performance and efficiency.
2. Low Noise: Employing advanced fluid dynamics technology to adjust blade angles for high airflow while minimizing noise levels.
3. Wide Application Range: Suitable for a diverse range of industries and environments, including industrial ventilation, HVAC systems, agriculture, construction, automotive, and more, offering flexible customized solutions (OEM/ODM).
4. Sustainable Development: Our fans are designed with energy-saving and environmentally friendly features. Utilizing new materials such as fiberglass-reinforced plastic, they meet eco-friendly energy requirements, withstand harsh working conditions, and provide long-term reliability.
5. Easy Installation and Maintenance: Equipped with installation grilles and duct mounting options, our fans feature user-friendly designs and easily maintainable components, facilitating hassle-free maintenance.
EC fans are widely applied in HVAc systems, especially where speedcontrol function is required and noise reduction matters.
Cooling
EC fans are essentially fans with brushless Dc motor, combining theadvantages of Ac and Dc power.
Air Purification
Apart from smart control and energy-saving, the compact size is oneof the significant features of EC fans.
Refrigeration
Energy-saving is the most important feature that will be taken into
consideration because the evaporator fan motors run twenty four
hours a day.
Automotive equipment
The EC brushless motorized fans can be used both in combustionengine thermal circuits and in electric vehicles.
Medical Equipment
EC fans, with high performance, efficient energy consumption, low
noise level,etc, are also favored in medical industry.























Reviews
There are no reviews yet.