This air cooled water chiller is published with the manufacturer’s full specification — 380 V, 10kw. Quantity and destination market determine the final price — tell us both for a firm quote.
Key Features of This Air Cooled Water Chiller
- Power: 4 kW(5.36hp)
- Compressor Power: 3 kw
- Voltage: 380 V
- Cooling Capacity: 10kw
- Chiller Air Flow: 4300 m3/h
- Chiller Refrigerant: R22 / R134a / R407c
Technical Specifications
| Voltage | 380 V |
|---|---|
| Power | 4 kW(5.36hp) |
| Warranty | 1 year |
| Machinery Test Report | Provided |
| Video Outgoing-Inspection | Provided |
| Key Selling Points | Easy To Operate |
| Core Components | PLC, Engine, Motor |
| Place Of Origin | Guangdong, China |
| Weight (Kg) | 170 |
| Brand Name | Anyda |
| Dimension(L*W*H) | 950*560*1150mm(37.40*22.05*45.28in) |
| Product Name | 10kw 4hp Air Cooled Water Chiller |
| Cooling Capacity | 10kw |
| Compressor Power | 3 kw |
| Chiller Compressor | Scroll |
| Chiller Air Flow | 4300 m3/h |
| Chiller Refrigerant | R22 / R134a / R407c |
| Chiller In/Out Pipe Size | G3/4" |
| Chiller Tank | 40 L |
| Pump Motor | 0.37 kw |
| Chiller Water Flow | 1.87m^3/h |
| Selling Units | Single item |
| Single Volume | 0 cm³ |
| Single Gross Weight | 0.0 kg |
Product Details
10kw 4hp Air Cooled Water Chiller
Anyda water chiller units are water-cooled type and air-cooled type. All models are equipped with compressor and pump overload protector, phase shortage and reversal alarm, anti – freeze thermostat, pressure gauge etc. They feature excellent performance and a long life span. This series of working flow is based on the basic principle of heat exchange. It is applicable to the industry that requires flow of precisely controlled chilled water, and considered as indispensable equipment for modern industry.
Applied Machinery: Cooling system of oil temperature, ultrasonic, high frequency machinery, injection molding machinery, blow molding machinery.
Main Features
It can adopt Sanyo,Copeland, Danfoss or other brand you inquiried.
2.Anyda air cooled chiller use high efficiency air side heat exchanger
Unique M-shaped design, inner grooved & patent sawtooth design and hydrophilic aluminum fin guarantee efficient heat exchange between the air side exchanger and ambient air.
3.Anyda air cooled chiller use shell & tube heat exchanger
Dry type & tube heat exchanger with inner grooved copper tube optimizes the cooling & heating efficiency. Self-cleaning, high intensity, anti-shaking design and heat insulation covering material ensure shell & tube heat exchanger unstained, reliable, quiet, highly efficient.
4.Anyda air cooled chiller equipped with complete protection
Water shortage protection, high/low voltage protection, anti-freezing protection, overload protection, overheat protection and oil level protection ensure high reliability and stability.
Machine Parts
Name: Compressor
Brand: Sanyo/ Copeland
Name: Condenser,Evaporator
Brand: Anyda
Name:Control Panel
Brand:Punp
Other Parts
Name: Electrical Parts
Brand: LG/Schneider
Name: Pump
Brand: Mini/CNP
1.How does a chiller system work?
Chiller has two circulation,one is process water circulation,the other is refrigerant gas circulation.Heat picked up from the process.Heat transfers to refrigerant circulation.Heat is remove to air or water.
2.How to calculate cooling capacity for chillers
Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-t2)/0.86
Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)
3.Types of chiller system?
Air Cooled Chiller and Water Cooled Chiller.Water cooled chiller needs a separated cooling tower and has a higher efficiency,but less easier than air cooled.
4. What type of the chiller should I use ?
It depend on the local environment temperature and water source. If lack of water and low ambient temp , we advise you use the air cooled chiller, if not , air cooled chiller is ok. But for installation,air cooled is more convenient than water cooled.
5. How to select the model of the chiller ?
It is better to tell us some parameter, such as : Cooling Capacity, Outlet Temperature, Power Supply,Environment Temperature, Application Field, Anti-rust Or Anti-corrosion, and so on.Meanwhile,we could do customized chiller according to your end user consumption.
6.Cooling capacity unit conversion?
1 kcal/h = 1.163W,1 W = 0.8598 kcal/h;
1 Btu/h = 0.2931W,1 W = 3.412 Btu/h;
1 USRT = 3.517 kW,1 kW = 0.28434 USRT;
1 kcal/h = 3.968 Btu/h,1 Btu/h = 0.252 kcal/h;
1 USRT = 3024 kcal/h,10000 kcal/h = 3.3069 USRT;
7.The chiller can heat?
Yes,by the electrical heating wire.Please kindly inform us the hot water temp or heating capacity.
8. What is production period ?
Generally speaking, it is 15-30 days,some standard model there are some stocks, but it all depend on the model ,quantity.
9.What is your company after-sales service ?
Our warranty period is one year. If there is any problem in this year, we will send you the new parts (not including freight )for replacement. Meanwhile, welcome to consulting the technical knowledge.
10.Chiller maintenance?
Step 1: Keep Tubes Clean
Step 2: Ensure a Leak-free Unit
Step 3: Sustain Proper Water Treatment(prevent scale, corrosion)
Step 4: Analyze Oil and Refrigerant
1.Reply your inquiry within 12 working hrs.
2.Strong R&D team,more than 15 years of manufacturing chiller experience. OEM&ODM is welcomed.
3.Direct factory,offer customer competitive price with high quality chiller.
4.Strict quality control system,professional QC team.
Ordering and Pricing
- Minimum order quantity: 1 set
- Volume pricing:
- 1+ set: US $1650 / set
- Ships from: China
- Customization: OEM and ODM accepted on qualifying volumes.
Frequently Asked Questions
What is the minimum order quantity for this air cooled water chiller?
The standard minimum order quantity is 1 set. Trial orders can usually be arranged for buyers evaluating the product before a full production run.
What warranty is provided?
The manufacturer provides a 1 year warranty. Spare parts and technical support remain available after the warranty period.
Can the air cooled water chiller be supplied for my local voltage?
The standard configuration is 380 V. Alternative voltage and frequency builds are available when specified at the time of order.
Do you accept OEM or custom branding?
Yes. Custom logo, colour, packaging and specification changes are accepted on qualifying order volumes. Send your artwork and technical requirements with your enquiry.
How long does production and delivery take?
In-stock configurations typically ship within 7–15 days. Customised or large-volume orders are usually produced in 25–35 days, confirmed on order.
About the Manufacturer
This product is produced by Shenzhen Anyda Refrigeration Equipment Co., Ltd., based in China. The company 10 years as a verified Alibaba.com supplier, operates its own manufacturing. Browse the full Shenzhen Anyda Refrigeration Equipment Co., Ltd. range on HVACR Nexus.
See more in Other Refrigeration & Heat Exchange Equipment on HVACR Nexus.