A kitchen that idles for hours and then produces several hundred covers in ninety minutes — sized for a peak it only meets occasionally, and silent enough that the function room never hears it.
- 2,308products across this application
- 733verified manufacturers
- 5equipment groups
WhatExtreme peaks against long idle periods
Hotel kitchens serve breakfast, à la carte and banqueting from broadly the same space, and banqueting is the design case: a full cooking line running flat out for a short, intense service, then nothing. Meanwhile the kitchen sits adjacent to function rooms and guest areas that must not hear it or smell it.
WhoWho buys it
Hotel groups, conference and banqueting venues, catering equipment consultants specifying fit-outs, and contractors refurbishing kitchens while the hotel continues to operate.
WhyWhy running at design flow all day is the real cost
A hood system sized for full banquet load and left at that flow wastes an enormous amount of tempered make-up air during the many hours the kitchen idles. In a hotel that runs a kitchen sixteen hours a day but cooks hard for three, the energy penalty of constant-volume extract is far larger than the equipment cost difference. Demand-based control is the single most valuable specification decision here.
HowSpecifying for the peak, running for the average
Size hoods and fans for the banquet peak, then control them on demand — temperature or optical sensing in the hood reduces extract when the line is idle, and make-up air follows. Insist on sound data at the specified duty, not just a headline figure, because the plant sits next to spaces where people are paying to hold events. And design heat recovery in from the start: with this much tempered make-up air, recovery is where the operating cost is decided.
Equipment this application needs
Hood extract
Centrifugal Fans702
Backward-curved with variable speed — sized for banquet peak, running at a fraction of it most of the day.
Make-up air
Axial Flow Fans672
Tracking extract so the kitchen stays balanced across the whole turndown range.
Heat recovery
Heat Exchangers362
Recovering from extract to temper incoming air — the main lever on running cost in a hotel kitchen.
Cold & freezer rooms
Condensing Units427
Back-of-house storage supporting banquet volumes.
Banquet & bar ice
Ice Machines75
Sized on event peak, not on daily average — a banquet consumes a day’s production in an hour.
What to check before you order
- Low Noise 504
- Plant adjoins function rooms and guest areas. Ask for sound power at the actual duty.
- Variable Speed 72
- The difference between paying for the peak all day and paying for what you use.
- High Temperature 250
- Continuous hot grease-laden extract during service.
- Heat Recovery 71
- Large tempered make-up air volumes make recovery pay back quickly.
- Stainless Steel 1,488
- Cleanable to the standard a hotel inspection expects.
Products for this application
-
- 230 V
- Power Source Electric
- Material Plastic
-
- 230 V
- Power Source Electric
- Material Plastic
-
- 110v
- 16 in
- Power Source Electric
-
- 220 V
- Stainless Steel
-
- 11 BTU
- 220V50Hz
- R-410A
-
- 120 V
- Power Source Electric
- Blade Material Plastic
-
- 110V~240V 50/60Hz
- Power Source Electric
- Stainless Steel
-
- Power Source Electric
- Stainless Steel
-
- AC 220V~240V
- Customized Size
- Power Source Electric
-
- 3200~4800m³/h
-
- 220 V
- Stainless Steel
- 66 dB
-
- 230V
- Aluminum Alloy
Questions buyers ask
How do you size a kitchen that is idle most of the day?
Why is heat recovery so important in a hotel kitchen?
How is noise handled next to function rooms?
Related applications
Tell us about your hotel & banquet kitchen ventilation project
Send the duty and site conditions and we will come back with matched equipment, price and lead time from the manufacturers listed here — usually within one working day.