Cooling Air Cooler. Key specification: 220V/1PH/50HZ, air flow 2*6000m^3/h. Ships factory-direct with the manufacturer’s data sheet. Type: Cooler.

Warranty
1 Year
Place Of Origin
Zhejiang, China
Voltage
220V/1PH/50HZ
Air Flow
2*6000m^3/h
Type
Cooler
  • Reply within one working day
  • Factory-direct pricing, OEM & ODM accepted
  • Full specification and test reports supplied
Also listed under

Get Factory Pricing

Free quotation direct from the manufacturer — price, MOQ and lead time, usually within one working day. No account needed.

Enquiring about Cooling Air Cooler, LANCO, 220V, 2*6000m^3

Cooling air cooler — 220V/1PH/50HZ, air flow 2*6000m^3/h. The complete factory specification follows. For a binding price and lead time, send the volume you need and where it ships to.

Key Features of This Cooling Air Cooler

  • Defrosting Power: 2.1KW
  • Fan Motor Power: 2*550W
  • Voltage: 220V/1PH/50HZ
  • Nominal Cooling Capacity: 2.2KW
  • Air Flow: 2*6000m^3/h
  • Casing Material: Galvanized Sheet With Plastic Spray

Technical Specifications

Core Components Motor
Machinery Test Report Provided
Warranty 1 Year
Video Outgoing-Inspection Provided
Weight (Kg) 120
Place Of Origin Zhejiang, China
Brand Name COOLTEMP
Casing Material Galvanized Sheet With Plastic Spray
Voltage 220V/1PH/50HZ
Test Pressure 2.8Mpa
Feature Long Service Life
Defrosting Power 2.1KW
Fan Motor Power 2*550W
Air Flow 2*6000m^3/h
Net Weight 120KG
Nominal Cooling Capacity 2.2KW
Heat Exchange Area 60m^2
Condition New
Applicable Industries hotels, Building Material Shops, Machinery Repair Shops, Manufacturing Plant, Food & Beverage Factory, Farms, Restaurant, Home Use, Retail, Food Shop, Construction works , Energy & Mining, Food & Beverage Shops, Advertising Company
Showroom Location None
Warranty Of Core Components 1 Year
Type Cooler
Selling Units Single item
Single Volume 0 cm³
Single Gross Weight 0.0 kg

Product Details

Product Description

Model LK-DD series Evaporator can be used as cooling device in varies cold storages, like simple cold storage or combined cold storage. There are type LK-DDH,LK-DDM and LK-DDL unit coolers, which are ideal for different refrigerating purposes. It's compact in structure, light in weight, no space occupation,high in efficiency to balance and lower refrigerating temperature.

Application:

Working with compressor condensing units of different refrigerating capacity,LK-DD series unit cooler is applied to different purposes of cold storage.LK-DDH type can be used at about 0°C for saving eggs and vegetables;LK-DDM type can be used at-18°C for saving meats and fishes; LK-DDL type can be used at-25°C or below for quick-freezing to preserve fresh meat and live fish.

Feature:

1. The housing is in plastic-sprayed coat or rolled from aluminum plate,best corrosion protection, beautiful in shape. 

2. Original coil arrangement to reduce the side resistance. The aluminum fins are fasten ed to the steel tubes by hydraulic expanding way, which is effective to reduce thermal contact resistance and improve thermal transfer. 

3. After pressure test, wash with trichloroethylene to clean the oily dirt,moisture, oxide and other impurities inside. As such, no blocking trouble after filling with refrigerant in use. 

4.Special fan motor, which is low in power consumption, large in air volume, low in noise, send far in air throw, guarantees good performance in humidity and low temperature. 

5.Equipped with U-shaped electro-thermal tube that's good in insulation inside the coil,rational gap arrangement and power capacity to achieve desirable defrosting performance. 

6.Groove-type channel clip, easy to install. 

7.Filled with nitrogen before leaving factory.

Cooling Air Cooler, LANCO, 220V, 2*6000m^3 - detail 1Cooling Air Cooler, LANCO, 220V, 2*6000m^3 - detail 2

Main Technical Parameter of LK-DDM Series Unit Cooler:

Model Norminal Cooling Capacity kw,troom=-18℃,Δt=(troom-t0)=7℃ Cooling area Pinch   FAN MOTOR      HEATING TUBE Remark
 QTY DIA φ  air volume range   motor power  voltage coil water pan voltage
 m∧2  mm pcs  mm  m∧3  m  w  v kw kw v Can be used for R134a R404A AND R502
LK-DDM7 1.4  7  6       1 300 1*2000  6 1*130  220 0.9 0.6 220
LK-DDM12  2.6  12  2 300 2*2000  6 2*130 0.9 0.6
LK-DDM15  3.0  15  300  2*2000  10  2*130  380   0.9 0.6
LK-DDM22  4.0  22  350  2*2500  10  2*135  1.2 0.6
LK-DDM30  5.0  30  400  2*3500  12  2*190  2.5 0.8
LK-DDM40 8 40 2 400 2*3500 12 2*190 2.8 0.8
LK-DDM60 12 60 2 450 2*5000 17 2*370 4.5 1
LK-DDM80 15.9 80 2 500 2*6000 17 3*1500 6 1
LK-DDM100 20 100 3 500 3*6000 17 3*550 7 1.2
LK-DDM120 24 120 3 500 3*6000 17 3*550 7.7 1.4
LK-DDM140 28 140 4 500 4*6000 17 4*550 9 1.5
LK-DDM160 32.1 160 4 500 4*6000 17 4*550 10.5 2
LK-DDM200  37.4  200  600  2*10000  20  2*1500  12.5 2.2
LK-DDM250  46.8  250  600  3*10000  22  3*1100  14 2.2
LK-DDM310 56.2 310 3 600 3*10000 22 3*1100 15 2.6
LK-DDM360 65.2 360 3 700 3*14000 22 3*2200 28 3
LK-DDM440 79.6 440 3 700 3*14000 22 3*2200 18.8 3.2

As for the cooling capacity under condition of the refrigeration is R22,troom=-18℃,At=7℃,we need to multiply the correction factor for the cooling capacity with refrigerant R134,QoR134a=QoR22*f.

 

Main Technical Parameter of LK-DDL Series Unit Cooler:

Model Norminal Cooling Capacity kw,troom=-18℃,Δt=(troom-t0)=7℃ Cooling area Pinch   FAN MOTOR      HEATING TUBE Remark
 QTY DIA φ  air volume range   motor power  voltage coil water pan voltage
 m∧2  mm pcs  mm  m∧3  m  w  v kw kw v Can be used for R134a R404A AND R502
LK-DDL8 1.2 8  9    1 300 1*2000 8 1*85  220 0.8 0.8 220
LK-DDL12  1.9  12 2 300 2*2000 8 2*85 0.9 0.9
LK-DDL15  2.3  15 350 2*2500  10  2*135  380   1.8 1
LK-DDL20   4.0 20 400  2*3500  12 2*190  2.4 1
LK-DDL30 5.1 30 400  2*3500  12  2*190  3.5 1
LK-DDL40 7.8 40 2 450 2*5000 17 2*550 4.8 1.2
LK-DDL55 9.8 55 2 500 2*6000 17 2*550 6.8 1.2
LK-DDL70 12.8 70 3 500 3*6000 17 3*550 7.8 1.5
LK-DDL80 15.7 80 3 500 3*6000 17 3*550 8.5 2
LK-DDL100 18.8 100 4 500 4*6000 17 4*550 10 2.2
LK-DDL115 21.6 115 4 500 4*6000 17 4*550 12 2.2
LK-DDL140 23.8 140 2 600 2*10000 22 2*1100 15 2.4
LK-DDL170  29 170 600  3*10000  22 3*1100  16 2.4
LK-DDL210 35.9 210  600  3*10000  22  3*1100  19 3
LK-DDL250 42.7 250 3 700 3*14000 22 3*2200 28 3
LK-DDL300 50.3 300 3 700 3*14000 22 3*2200 28.8 3.2

As for the cooling capacity under condition of the refrigeration is R22,troom=0℃,At=7℃,we need to multiply the correction factor for the cooling capacity with refrigerant R134,QoR134a=QoR22*f. 

 

Main Technical Parameter of LK-DDH Series Unit Cooler:

Model Norminal Cooling Capacity kw,troom=-18℃,Δt=(troom-t0)=7℃ Cooling area Pinch   FAN MOTOR      HEATING TUBE Remark
 QTY DIA φ  air volume range   motor power  voltage coil water pan voltage
 m∧2  mm pcs  mm  m∧3  m  w  v kw kw v Can be used for R134a R404A AND R502
LK-DDH10 2.2 10  4.5      1 300 1*2000 8 1*130  220 0.5 0.5 220
LK-DDH15  3.3 15  2 300 2*2000 8 2*130 0.8 0.8
LK-DDH20  4.2 20  300  2*2000  10 2*135 380   0.9 0.6
LK-DDH25  5.2 25  350  2*2500  10 2*135  1.2 0.6
LK-DDH40  8.1 40 400  2*3500  12  2*190  1.4 0.6
LK-DDH55 11.2 55 2 400 2*3500 12 2*190 1.8 0.8
LK-DDH80 16.2 80 2 450 2*5000 17 2*550 2.8 0.8
LK-DDH105 21.6 105 2 500 2*6000 17 2*550 3 0.8
LK-DDH125 25.5 125 3 500 3*6000 17 3*550 4.5 0.8
LK-DDH160 34.2 160 3 500 3*6000 17 3*550 5.5 0.8
LK-DDH185 38.7 185 4 500 4*6000 17 4*550 6 1.2
LK-DDH210 42.8 210 4 500 4*6000 17 4*550 7.5 1.4
LK-DDH260 52.6 260 600  2*10000  22 2*1100  9 1.5
LK-DDH330  67.7  30 600  3*10000  22 3*1100  11 1.5
LK-DDH410 82.6 410 3 600 3*10000 22 3*1100 12.5 2
LK-DDH470 95.6 470 3 700 3*14000 22 3*2200 15 2.5
LK-DDH580 117 580 3 700 3*14000 22 3*2200 16.2 2.7

we need to multiply the correction factor for the cooling capacity with refrigerant R134,QoR134a=QoR22*f.  

Cooling Air Cooler, LANCO, 220V, 2*6000m^3 - detail 3Cooling Air Cooler, LANCO, 220V, 2*6000m^3 - detail 4

Cooling Air Cooler, LANCO, 220V, 2*6000m^3 - detail 5Cooling Air Cooler, LANCO, 220V, 2*6000m^3 - detail 6Cooling Air Cooler, LANCO, 220V, 2*6000m^3 - detail 7Cooling Air Cooler, LANCO, 220V, 2*6000m^3 - detail 8Cooling Air Cooler, LANCO, 220V, 2*6000m^3 - detail 9Cooling Air Cooler, LANCO, 220V, 2*6000m^3 - detail 10 

Related Products

Cooling Air Cooler, LANCO, 220V, 2*6000m^3 - detail 11Cooling Air Cooler, LANCO, 220V, 2*6000m^3 - detail 12

Packaging & Shipping

 Cooling Air Cooler, LANCO, 220V, 2*6000m^3 - detail 13Cooling Air Cooler, LANCO, 220V, 2*6000m^3 - detail 14

Our Services

 Cooling Air Cooler, LANCO, 220V, 2*6000m^3 - detail 15Cooling Air Cooler, LANCO, 220V, 2*6000m^3 - detail 16Cooling Air Cooler, LANCO, 220V, 2*6000m^3 - detail 17Cooling Air Cooler, LANCO, 220V, 2*6000m^3 - detail 18Cooling Air Cooler, LANCO, 220V, 2*6000m^3 - detail 19Cooling Air Cooler, LANCO, 220V, 2*6000m^3 - detail 20

Ordering and Pricing

  • Minimum order quantity: 1 piece
  • Volume pricing:
    • 1–4 piece: US $315 / piece
    • 5–19 piece: US $294 / piece
    • 20+ piece: US $273 / piece
  • Ships from: China
  • Customization: OEM and ODM accepted on qualifying volumes.

Frequently Asked Questions

What is the minimum order quantity for this cooling air cooler?

The standard minimum order quantity is 1 piece. Trial orders can usually be arranged for buyers evaluating the product before a full production run.

What warranty is provided?

The manufacturer provides a 1 Year warranty. Spare parts and technical support remain available after the warranty period.

Can the cooling air cooler be supplied for my local voltage?

The standard configuration is 220V/1PH/50HZ. Alternative voltage and frequency builds are available when specified at the time of order.

Do you accept OEM or custom branding?

Yes. Custom logo, colour, packaging and specification changes are accepted on qualifying order volumes. Send your artwork and technical requirements with your enquiry.

How long does production and delivery take?

In-stock configurations typically ship within 7–15 days. Customised or large-volume orders are usually produced in 25–35 days, confirmed on order.

About the Manufacturer

This product is produced by Shengzhou Lanco Refrigeration Equipment Co., Ltd., based in China. The company 10 years as a verified Alibaba.com supplier, Trading Company. Browse the full Shengzhou Lanco Refrigeration Equipment Co., Ltd. range on HVACR Nexus.

Core Components

Motor

Machinery Test Report

Provided

Warranty

1 Year

Video Outgoing-Inspection

Provided

Weight (Kg)

120

Place Of Origin

Zhejiang, China

Brand Name

COOLTEMP

Casing Material

Galvanized Sheet With Plastic Spray

Voltage

220V/1PH/50HZ

Test Pressure

2.8Mpa

Feature

Long Service Life

Defrosting Power

2.1KW

Fan Motor Power

2*550W

Air Flow

2*6000m^3/h

Net Weight

120KG

Nominal Cooling Capacity

2.2KW

Heat Exchange Area

60m^2

Condition

New

Applicable Industries

hotels, Building Material Shops, Machinery Repair Shops, Manufacturing Plant, Food & Beverage Factory, Farms, Restaurant, Home Use, Retail, Food Shop, Construction works , Energy & Mining, Food & Beverage Shops, Advertising Company

Showroom Location

None

Warranty Of Core Components

1 Year

Type

Cooler

Selling Units

Single item

Single Volume

0 cm³

Single Gross Weight

0.0 kg

More from Shengzhou Lanco Refrigeration Equipment Co., Ltd.

Other equipment from the same manufacturer — one enquiry can cover several items.

Compare Other Air Coolers

Alternatives in the same category, from different verified suppliers.

Explore related

Feature
220V